...Transformer on-Load Tap-Changer Tester Fast and Accurate Product Description The on-load tap-changer is the only moving part that is connected to the transformer circuit, so the detection of the on-load tap-changer is getting more and more attention. In the "Procedures for Handling and Preventive Tests for Electrical Equipment", it is required to check the sequence of actions and the switching time of the on-load tap
...Transformer on-Load Tap-Changer Tester Fast and Accurate Product Description The on-load tap-changer is the only moving part that is connected to the transformer circuit, so the detection of the on-load tap-changer is getting more and more attention. In the "Procedures for Handling and Preventive Tests for Electrical Equipment", it is required to check the sequence of actions and the switching time of the on-load tap more
Brand Name:XZH TEST
Model Number:XHYZ1668A
Place of Origin:Xi'an, Shaanxi, China
-
Product details Multi-Current Transformer On Load Tap Switch Tester With 0.3A/0.5A/1A/2A Output Product Description ZXYZ-2002 Transformer On Load Tap Switch Tester is mainly used for measuring transformer on-load tap switch transition waveform, transition ...
-
... Transformer on Load Tap Changer Tester Introduction: OLTC Automatic Transformer On Load Tap Changer Tester can record switch operation waveform in overall process. The longest time is 6.4s. OLTC Automatic Transformer On Load Tap Changer Tester can ...
... Transformer on Load Tap Changer Tester Introduction: OLTC Automatic Transformer On Load Tap Changer Tester can record switch operation waveform in overall process. The longest time is 6.4s. OLTC Automatic Transformer On Load Tap Changer Tester can ... more
Brand Name:Delta
Model Number:OLTC
Place of Origin:China
Oltc Automatic Transformer on Load Tap Changer Tester
-
Transformer OLTC Tester Model: TCT-100 Able to test on-load tap changer of power transformers Transformer OLTC Tester TCT-100 is used to measure the transition waveform, transition time, transition resistance and three-phase synchronization of on-load tap changer of power transformers...
Transformer OLTC Tester Model: TCT-100 Able to test on-load tap changer of power transformers Transformer OLTC Tester TCT-100 is used to measure the transition waveform, transition time, transition resistance and three-phase synchronization of on-load tap changer of power transformers... more
Brand Name:HAOMAI
Model Number:TCT-100
Place of Origin:China
OLTC Transformer On Load Tap Changer Tester 0-320ms Ultraportable
-
... phase. 1 Test transformers of type Y0 Y Δ and display resistance value directly; 2 Automatically analyze waveform fault and mark the fault. 3 Automatically adjust resistance value and time range according to sampling data 4 Transformer type Δ is able to
... phase. 1 Test transformers of type Y0 Y Δ and display resistance value directly; 2 Automatically analyze waveform fault and mark the fault. 3 Automatically adjust resistance value and time range according to sampling data 4 Transformer type Δ is able to more
Brand Name:Huaying
Place of Origin:Wuhan,Hubei,China
Price:email whhy818@163.com
On load tap changer tester
-
...Transformer On-load Tap-changer Characteristics Tester , Transformer Tap-changer Tester I. Products Description and Application FKC-1A Tester is a comprehensive test equipment which is used to measure and analyze electrical properties index of on-load tap-changer of power transformer and special transformer...
...Transformer On-load Tap-changer Characteristics Tester , Transformer Tap-changer Tester I. Products Description and Application FKC-1A Tester is a comprehensive test equipment which is used to measure and analyze electrical properties index of on-load tap-changer of power transformer and special transformer... more
Brand Name:Fanke High-Voltage
Model Number:FKC-1A
Place of Origin:China
Durable Power Transformer Testing Equipment For On Load Tap Changer Test
-
... supply (RMS) standards, for a variety of quad other three-phase, single-phase on-load voltage regulating transformer tap-changer action features communicate with winding measurement, directly display tap-changer action in the process of test waveform in
-
...load tap changer tester HYKC-2000 2. Equipment Description: On load tap changer analyzer HYKC-2000 is mainly applied to test transient time, transition waveform, transition resistance, synchronization status of three phase. 3. Main Functions: 1 Test transformers...
...load tap changer tester HYKC-2000 2. Equipment Description: On load tap changer analyzer HYKC-2000 is mainly applied to test transient time, transition waveform, transition resistance, synchronization status of three phase. 3. Main Functions: 1 Test transformers... more
Brand Name:Huaying
Model Number:Huaying Series
Place of Origin:Wuhan Hubei China
On-Load Tap Changer Analyzer
-
...Load Tap Changer Distribution Transformer Product Description: Power transformer three phase oil immsered electrical transformer rated voltage during 6-35kV, oil immersed transformer are most used in power plant,power grid transmission and distribution station,industry& commerce electrical substation as the electrical equipment of power transmission, 1,Two windings or three windings 2,On-load or no-load...
...Load Tap Changer Distribution Transformer Product Description: Power transformer three phase oil immsered electrical transformer rated voltage during 6-35kV, oil immersed transformer are most used in power plant,power grid transmission and distribution station,industry& commerce electrical substation as the electrical equipment of power transmission, 1,Two windings or three windings 2,On-load or no-load... more
Brand Name:Tianan Electric
Model Number:S11
Place of Origin:China
On - Load Tap Changer Oil Immersed Distribution Transformer 33 Kv 5000kva
-
...Transformer 200KV BIL On-Load-Tap 38.5KV Features: 1) On the basis of S9 series, the no-load loss of S11-S13 series products is reduced by 30% on average, and the no-load current is reduced by 70%-85% compared with S9 series. 2) Transformer tank adopts fully sealed structure, which can be bolted or welded along the tank. Transformer...
...Transformer 200KV BIL On-Load-Tap 38.5KV Features: 1) On the basis of S9 series, the no-load loss of S11-S13 series products is reduced by 30% on average, and the no-load current is reduced by 70%-85% compared with S9 series. 2) Transformer tank adopts fully sealed structure, which can be bolted or welded along the tank. Transformer... more
Brand Name:WINLEY
Model Number:S11-1600KVA
Place of Origin:CHINA
1600KVA Airport Oil And Dry Type Transformer 200KV BIL On-Load-Tap 38.5KV
-
...transformer S11,30-2500KVA,10KV series,3 phae/full sealed/double winding Hengfengyou covers a wide range of Oil Filled Power Transformers with On Load Tap Changer (up to 2500 KVA in 11 KV & 33 KV Class) conforming to the international standards of quality and safety. These transformers...
...transformer S11,30-2500KVA,10KV series,3 phae/full sealed/double winding Hengfengyou covers a wide range of Oil Filled Power Transformers with On Load Tap Changer (up to 2500 KVA in 11 KV & 33 KV Class) conforming to the international standards of quality and safety. These transformers... more
Brand Name:HENGFENGYOU
Model Number:S11
Place of Origin:Qingdao,China
Oil Cooled Power Transformer 5000KVA 33KV / 11KV with OLTC On Load Tap Changer
-
Transformer On-load Tap Changer Test Instrument I. Introduction: The on load tap changer test instrument can record switch operation waveform in overall process. The longest time is 6.4s.It can test various parameters such as ...
-
...Loading Rockwell Hardness Tester With Digital Display Resolution 0.1HR Brief Introduction: iqualitrol HR-150E equips with digital display to show hardness results directly with resolution 0.1HR, the accuracy is much better than dial reading. The electric digital Rockwell hardness tester adopts the automatic loading and unloading test force mechanism, and the test force transformation is obtained by the rotation of the variable load
...Loading Rockwell Hardness Tester With Digital Display Resolution 0.1HR Brief Introduction: iqualitrol HR-150E equips with digital display to show hardness results directly with resolution 0.1HR, the accuracy is much better than dial reading. The electric digital Rockwell hardness tester adopts the automatic loading and unloading test force mechanism, and the test force transformation is obtained by the rotation of the variable load more
Brand Name:iqualitrol
Model Number:HR-150E
Motorized Loading Rockwell Hardness Tester With Digital Display Resolution 0.1HR
-
Power transformer EI type pcb mounting laminated core Z11 0.35T load voltage 24V 48V current 50mA The products are mainly used in various types of Access Controller, Building Intercom, Safety& Security Power Supply, network, DVD, monitors, computer, ...
-
Product Introduction: For current transformers, to be completed: 1. Volt-ampere characteristics of the test; 2. Current ratio test; (can measure three secondary windings) 3. Polarity discrimination; 4.10% error curve; 5. AC voltage secondary winding; 6, ...
Product Introduction: For current transformers, to be completed: 1. Volt-ampere characteristics of the test; 2. Current ratio test; (can measure three secondary windings) 3. Polarity discrimination; 4.10% error curve; 5. AC voltage secondary winding; 6, ... more
Brand Name:chinacoal
Place of Origin:China
Certification:ISO9001,CE
Comprehensive transformer tester
-
... by load, be fit for test of mid&small transformer. 3) good protection, reliability of anti-protential impact to the kit. 4) have discharge alarm&display, can reduce misoperation 5) can swtich on load tap-changer directly under testing, refreshing data
... by load, be fit for test of mid&small transformer. 3) good protection, reliability of anti-protential impact to the kit. 4) have discharge alarm&display, can reduce misoperation 5) can swtich on load tap-changer directly under testing, refreshing data more
Brand Name:HNMC
Model Number:MCZR series
Place of Origin:China
Lab Insulation Resistance Test Set , 60A DC Resistance Tester
-
... with resolution 0.1HR, the accuracy is much better than dial reading. The electric digital Rockwell hardness tester adopts the automatic loading and unloading test force mechanism, and the test force transformation is obtained by the rotation of the