-
FBM214B RH927AH FOXBORO I/A Series HART Input Module Quick Details 1.Factory direct supply,competitive price. 2.Professional Experience of inverter more than 10 year. 3.Prompt delivery and remarkable services. 4.100% new materials for production and 100...
FBM214B RH927AH FOXBORO I/A Series HART Input Module Quick Details 1.Factory direct supply,competitive price. 2.Professional Experience of inverter more than 10 year. 3.Prompt delivery and remarkable services. 4.100% new materials for production and 100... more
Brand Name:FOXBORO
Model Number:FBM214B RH927AH
Place of Origin:USA
-
... connection it can also interface 4-wire transmitters without losing the HART capability. The AI895 Analog Input Module has 8 channels. The module includes Intrinsic Safety protection components on each channel for connection to process equipment in
-
...Series Power Supply Module Brand New In Original Description: Brand Honeywell Model Number TC-CCR013 Type I/O Module Lead Time 3-5 days Voltage 24V Warranty 1 Year High Level Analog Input /HART Input Module (16pt) – The High Level Analog Input Module supports both high level analog and HART inputs. Analog inputs are typically 4-20mA DC for both traditional and HART devices. HART data can be used for status and configuration. HART
...Series Power Supply Module Brand New In Original Description: Brand Honeywell Model Number TC-CCR013 Type I/O Module Lead Time 3-5 days Voltage 24V Warranty 1 Year High Level Analog Input /HART Input Module (16pt) – The High Level Analog Input Module supports both high level analog and HART inputs. Analog inputs are typically 4-20mA DC for both traditional and HART devices. HART data can be used for status and configuration. HART more
Brand Name:HONEYWELL
Model Number:TC-CCR013
Place of Origin:America
Honeywell TC-CCR Series Power Supply Module Brand New In Original
-
... can be implemented in a redundant fashion to provide a solution with no single point of failure. Its highly flexible modules can be placed both local and remote to the control processor. The additional benefits of using Series C include: Greater I/O
... can be implemented in a redundant fashion to provide a solution with no single point of failure. Its highly flexible modules can be placed both local and remote to the control processor. The additional benefits of using Series C include: Greater I/O more
Brand Name:Honeywell
Model Number:CC-PAIH02
Place of Origin:USA
HONEYWELL CC-PAIH02 SERIES C HART ANALOG INPUT MODULE
-
... Series 8 Controller and I/O system. It is designed for use in a variety of industrial automation applications, including process control, manufacturing, and oil and gas. High-level AI HART functionality for advanced process control Single-ended inputs for
... Series 8 Controller and I/O system. It is designed for use in a variety of industrial automation applications, including process control, manufacturing, and oil and gas. High-level AI HART functionality for advanced process control Single-ended inputs for more
Brand Name:Honeywell
Model Number:8C-PAIHA1
Place of Origin:USA
8C-PAIHA1 51454470-275 Honeywell Hart Analog Input Module
-
...HART Communication Input Interface Module features eight 4 to 20 mA group-isolated analog input channels. It supports any combination of standard 4 to 20 mA devices and HART devices, providing flexibility for a variety of field instrumentation. 02. As a HART communications field device host, the FBM214 allows the I/A Series...
...HART Communication Input Interface Module features eight 4 to 20 mA group-isolated analog input channels. It supports any combination of standard 4 to 20 mA devices and HART devices, providing flexibility for a variety of field instrumentation. 02. As a HART communications field device host, the FBM214 allows the I/A Series... more
Brand Name:FOXBORO
Model Number:FBM214
Place of Origin:USA
Foxboro FBM214 HART Communication Module with 8 Group-Isolated Channels
-
...INPUT MODULE 8CHANNEL HART ANALOG TC-HAI081 The C300 / CF9 IOTA is a combination board that joins a Series C C300 IOTA with a Series C CF9 IOTA. The dimensions of the C300/CF9 IOTA and the UHIO IOTA are the same, 8.66X8.37 inches. The following figure displays the engineering drawing of the C300/CF9 IOTA The Series C UHIO is comprised of the following Series...
...INPUT MODULE 8CHANNEL HART ANALOG TC-HAI081 The C300 / CF9 IOTA is a combination board that joins a Series C C300 IOTA with a Series C CF9 IOTA. The dimensions of the C300/CF9 IOTA and the UHIO IOTA are the same, 8.66X8.37 inches. The following figure displays the engineering drawing of the C300/CF9 IOTA The Series C UHIO is comprised of the following Series... more
Brand Name:Honeywell
Model Number:TC-HAI081
Place of Origin:United States
Honeywell TC-HAI081 INPUT MODULE 8CHANNEL HART ANALOG TC-HAI081
-
... CC-PAIH01 51405038-175 HART ANALOG INPUT MODULE Lead time:3-5 days New with one year warranty We have good price on Honeywell C200,C300,model number such like TC/TK/MC/CC/511/512/513/514/900 and some FC series goods, If you have other
-
Honeywell PLC 8C-PAIHA1 Series 8 Controller 51454470-275 HART Analog Input Module Product Details: Brand Name Honeywell Model 8C-PAIHA1 Product ID 51454470-275 Condition New Gross Weight 3kg ...
-
...Input Module 0…20 MA I. Product Overview The ABB AI815 is an 8-channel current-type analog input module in the S800 I/O series, designed for high-precision and high-reliability process control. Each AI815 supports dual ranges of 0…20 mA and 4…20 mA with up to 16-bit resolution. It features a built-in HART...
...Input Module 0…20 MA I. Product Overview The ABB AI815 is an 8-channel current-type analog input module in the S800 I/O series, designed for high-precision and high-reliability process control. Each AI815 supports dual ranges of 0…20 mA and 4…20 mA with up to 16-bit resolution. It features a built-in HART... more
Brand Name:ABB
Model Number:AI815 3BSE052604R1
Place of Origin:Sweden
ABB AI815 3BSE052604R1 S800 I/O 8 Channel Current Type Analog Input Module 0…20 MA
-
...Module COATED S8 AO IOM (16) Honeywell PLC Description: SERIES 8 AO NONHART-1 IOM (16), COATED I/O Modules (IOMs) This document provides technical information to configure the Series 8 I/O. The following Series 8 I/O items are included in this document. • TC/RTD • Analog Input – Single Ended • Analog Input with HART – Single Ended • Analog Input with HART – Differential • Analog Output • Analog Output with HART...
...Module COATED S8 AO IOM (16) Honeywell PLC Description: SERIES 8 AO NONHART-1 IOM (16), COATED I/O Modules (IOMs) This document provides technical information to configure the Series 8 I/O. The following Series 8 I/O items are included in this document. • TC/RTD • Analog Input – Single Ended • Analog Input with HART – Single Ended • Analog Input with HART – Differential • Analog Output • Analog Output with HART... more
Brand Name:Honeywell
Model Number:8C-PAONA1
Place of Origin:USA
Analoge Output coated S8 AO IOM 8C-PAONA1 Honeywell PLC Module
-
.... The FBM214 supports any mix of standard 4 to 20 mA devices and HART devices. The FBM214 serves as a HART communications field device host, enabling the I/A Series system to request and receive two digital messages per second from the field device.
.... The FBM214 supports any mix of standard 4 to 20 mA devices and HART devices. The FBM214 serves as a HART communications field device host, enabling the I/A Series system to request and receive two digital messages per second from the field device. more
Brand Name:Foxboro
Model Number:FBM214
Place of Origin:USA
FBM214 Foxboro PLC HART Communication Input Interface Module
-
...Module Kit ABB PLC Module About 800xA Series The AI810 Analog Input Module has 8 current and voltage inputs. The inputs are independent for each channel, in that either voltage or current can be measured. The current input is able to handle a short circuit to the transmitter supply without damage. The input withstands HART communication. Nominal input...
...Module Kit ABB PLC Module About 800xA Series The AI810 Analog Input Module has 8 current and voltage inputs. The inputs are independent for each channel, in that either voltage or current can be measured. The current input is able to handle a short circuit to the transmitter supply without damage. The input withstands HART communication. Nominal input... more
Brand Name:ABB
Model Number:CI854AK01
Place of Origin:Sweden
CI854AK01 Profibus DP-VI Communication Module Kit ABB PLC Module
-
...Input GI/IS IOTA Product Description: The Honeywell CC-GAIX11 is an analog input module for the Experion Series-C I/O system. It is a general purpose input module that can be used to measure a variety of analog signals, including 4-20mA, voltage, and RTD signals. The module is isolated, which means that it is protected from electrical noise and transients. It is also HART...
...Input GI/IS IOTA Product Description: The Honeywell CC-GAIX11 is an analog input module for the Experion Series-C I/O system. It is a general purpose input module that can be used to measure a variety of analog signals, including 4-20mA, voltage, and RTD signals. The module is isolated, which means that it is protected from electrical noise and transients. It is also HART... more
Brand Name:Honeywell
Model Number:CC-GAIX11
Place of Origin:U.S.A
CC-GAIX11 Honeywell Analog Input GI/IS IOTA 100% Original
-
Smart valve positioner, flameproof explosion-proof Exd, straight stroke, double acting, fail lock TROLEO series intelligent valve positioner is composed of microprocessor main circuit board, local user interface (LCD display), input circuit, pneumatic ...
Smart valve positioner, flameproof explosion-proof Exd, straight stroke, double acting, fail lock TROLEO series intelligent valve positioner is composed of microprocessor main circuit board, local user interface (LCD display), input circuit, pneumatic ... more
Brand Name:TORLEO
Model Number:TOP-5879F1-C41GY-LDB
Place of Origin:China
Aluminum Pneumatic Control Valve Positioner HART Double Acting C41GY-LDB