... withstand voltage, the current national standard factory frequency voltage frequency defined as 45Hz ~ 65Hz, but in many test situations, requirements of generator is 50Hz plus or minus 2Hz ac testing, and generator stator winding of electric capacity is
... withstand voltage, the current national standard factory frequency voltage frequency defined as 45Hz ~ 65Hz, but in many test situations, requirements of generator is 50Hz plus or minus 2Hz ac testing, and generator stator winding of electric capacity is more
Brand Name:GDZX
Model Number:ZXGXZ
Place of Origin:China
-
... AC hipot test with variable frequency resonant circuit technology for above 110kV~800KV class GIS and other HV electrical facilities ; The highest test voltage is no more than 200KV,400KV,600KV or 800KV through modular HV test reactors in parallel or in
-
...test voltage is adjustable which would lead to series resonance in testing circuit. Both the conductors connected in test circuit in series and the capacitors connected in test circuit in parallel are also adjustable. That makes the resonance test set is
...test voltage is adjustable which would lead to series resonance in testing circuit. Both the conductors connected in test circuit in series and the capacitors connected in test circuit in parallel are also adjustable. That makes the resonance test set is more
Brand Name:AI
Model Number:RTS
Place of Origin:China
GIS Substation Cable Testing Equipment High Voltage Resonance Test Set
-
... AC hipot test with variable frequency resonant circuit technology for above 110kV~800KV class GIS and other HV electrical facilities ; The highest test voltage is no more than 200KV,400KV,600KV or 800KV through modular HV test reactors in parallel or in
... AC hipot test with variable frequency resonant circuit technology for above 110kV~800KV class GIS and other HV electrical facilities ; The highest test voltage is no more than 200KV,400KV,600KV or 800KV through modular HV test reactors in parallel or in more
Brand Name:Fanke
Model Number:CHX-4800KVA/200KV,400KV,600KV,800KV
Place of Origin:CHINA
30-300Hz Frequency High Voltage Resonant Test System With V/F Power Source
-
... and other capacitive test object. Comprising of 1) Variable Frequency control box 2) Excitation transformer 3) Reactor 4) Capacitance voltage divider Technical Parameters Output capacity 50kVA-12000kVA Output voltage 0-1500KV Power supply AC 380V+/-10%,
-
...High Voltage Resonant Capacitor Electronic Components Technical Parameter Reference Standards GB/T 17702 IEC 61071 Operating Temperature Range -40℃~85℃, Tmax +85℃ Capacity Range 0.004μF-8.0uF Rated Voltage 400VDC-3000VDC Capacity Tolerance ±5%(J) ;±10%(K) Withstand voltage Vt-t:1.5UN(dc) 60S 20℃ Vt-c:1000+2xUn/ 50HZ 60S (min 3000VAC) Insulation Resistance RC>3000S;at 100VDC; 25℃±5℃,60s Application Widely used in high voltage, high
...High Voltage Resonant Capacitor Electronic Components Technical Parameter Reference Standards GB/T 17702 IEC 61071 Operating Temperature Range -40℃~85℃, Tmax +85℃ Capacity Range 0.004μF-8.0uF Rated Voltage 400VDC-3000VDC Capacity Tolerance ±5%(J) ;±10%(K) Withstand voltage Vt-t:1.5UN(dc) 60S 20℃ Vt-c:1000+2xUn/ 50HZ 60S (min 3000VAC) Insulation Resistance RC>3000S;at 100VDC; 25℃±5℃,60s Application Widely used in high voltage, high more
Brand Name:GDHY
Model Number:C42102105JX12-01
Place of Origin:GUANGZHOU GUANGDONG
1.0uf 1000VDC High Voltage Resonant Capacitor Electronic Components
-
... Series Partial Discharge Tester is a state-of-the-art high voltage partial discharge tester designed for rigorous testing of insulation integrity in devices such as high voltage isolation ICs (e.g., optocouplers, magnetic couplers, isolation amplifiers,
-
...High Voltage Impulse Test Generator for EV Charging Equipment Complied Standards & Clauses The Impulse Test Generator conforms to the standard requirements of IEC 61851-1 clause 12.7, IEC 61851-23 clause 11.4, etc. Equipments Overview It is used to verify that the appliances shall withstand the transient over-voltages to which they may be subjected. The impulse voltage test is a destructive test in which a breakdown occurs if the test
...High Voltage Impulse Test Generator for EV Charging Equipment Complied Standards & Clauses The Impulse Test Generator conforms to the standard requirements of IEC 61851-1 clause 12.7, IEC 61851-23 clause 11.4, etc. Equipments Overview It is used to verify that the appliances shall withstand the transient over-voltages to which they may be subjected. The impulse voltage test is a destructive test in which a breakdown occurs if the test more
Brand Name:Sinuo
Model Number:SN1104-20KV
Place of Origin:China
IEC 61851 High Voltage Impulse Test Generator for EV Charging Equipment
-
... High Voltage Differential Probe, 70MHz Bandwidth And ±3000V, For High Voltage Circuit Testing Such As Inverters And New Energy Key Features: 1. Wide range and high precision ±3000V peak differential voltage covers the test requirements of high-voltage ...
-
... resistance Feature Electric drive Weight 55kg Volume 42.5×16×100cm Test standard UL, CSA, VDE, BS, SAA, FCC 2.Product Summary: Insulation resistance tester is specialized in testing voltage resistance of various electric apparatus and materials,
-
High Voltage Relay Test System , 7 phase AC / RJ45 / GPS Mode K3066L Relay protection test devices 1.Easy test 2.operation menu, Simple operation 3.Nominal input voltage:220VAC 4.Power:2000VA Friendly PC software for easy operation! K30 series relay tester...
High Voltage Relay Test System , 7 phase AC / RJ45 / GPS Mode K3066L Relay protection test devices 1.Easy test 2.operation menu, Simple operation 3.Nominal input voltage:220VAC 4.Power:2000VA Friendly PC software for easy operation! K30 series relay tester... more
Brand Name:Kingsine
Model Number:K3066L
Place of Origin:China
High Voltage Relay Test Device , 7 Phase AC / RJ45 / GPS Mode K3066L
-
High Voltage Cable Testing Equipments 64 Points / 128 Points With Short Circuit Test function: 1, short circuit, open circuit, poor conduction, low voltage insulation, high voltage insulation, jump spark, instant short / open circuit, single-ended test, sequential test 2, the machine can self-detection, With short circuit, poor insulation test. 3, the test...
High Voltage Cable Testing Equipments 64 Points / 128 Points With Short Circuit Test function: 1, short circuit, open circuit, poor conduction, low voltage insulation, high voltage insulation, jump spark, instant short / open circuit, single-ended test, sequential test 2, the machine can self-detection, With short circuit, poor insulation test. 3, the test... more
Brand Name:Kinte
Model Number:L2000HV
Place of Origin:Guangdong,China (Mainland)
High Voltage Cable Testing Equipments 64 Points / 128 Points With Short Circuit
-
...Test Chambers HAST (Highly Accelerated Stress Test) chambers reduce the time it takes to complete humidity testing for semiconductors. By elevating temperatures above 100°C and increasing the pressure, simulation of normal humidity tests can be made while
-
...test chamber, IEC 60587 Standards High Voltage Tracking Testing Equipment Description: High Voltage tracking tester suit for electronic products, household appliances and other materials resistance to tracking and erosion test, simulate the frequency (48HZ-62HZ) or a corresponding DC Voltage...
...test chamber, IEC 60587 Standards High Voltage Tracking Testing Equipment Description: High Voltage tracking tester suit for electronic products, household appliances and other materials resistance to tracking and erosion test, simulate the frequency (48HZ-62HZ) or a corresponding DC Voltage... more
Brand Name:HTI
Model Number:HTB-033
Place of Origin:Guangdong,China(Mainland)
ASTM D 2303 Erosion Resistance Test Chamber High Voltage Tracking Testing Equipment
-
...electrode was used, and the force of the two poles on the sample was 1.0 N; 0.05 N, respectively. The applied voltage is adjustable between 100 and 600V (48-60Hz), and the short-circuit current is 1.0; 0.1A, the voltage drop should not exceed 10%. When the
-
...Voltage Test", IEC60060 "High Voltage Test Technology" and UL1581, UL62, VDE, CCC, JIS, CSA, KEMA test standards. Features: 1. Full digital program control and pressure regulation 2. Automatic / manual operation mode 3. High and low voltage,