Product Description: One of the key features of the Gas Module (NEW) is its fast warm-up time. In less than a minute, the module is ready to detect any gas that comes its way. This makes it an ideal choice for applications where rapid gas detection is ...
Product Description: One of the key features of the Gas Module (NEW) is its fast warm-up time. In less than a minute, the module is ready to detect any gas that comes its way. This makes it an ideal choice for applications where rapid gas detection is ... more
Brand Name:SUSA
Model Number:4O3-CS
Place of Origin:USA
-
1: module interface can choose analog voltage output, TTL digital output UART interface, 485 signal output three; 2: sensor in principle can choose HONEYWELL, CITY, ALPHASENSE, three brands; 3: sensor module to be customized, the order cycle of about 7-15 ...
-
.... The module uses RoHS electrode electrochemical sensor as sensing element (the specific technical parameters of the sensor are detailed in the data manual), and realizes the gas concentration detection under the control of sampling circuit, which
.... The module uses RoHS electrode electrochemical sensor as sensing element (the specific technical parameters of the sensor are detailed in the data manual), and realizes the gas concentration detection under the control of sampling circuit, which more
Brand Name:kacise
Model Number:KOX501
Place of Origin:CHINA
UART Output Electrochemical Gas Sensor For Air Quality
-
...Gas Sensor(O2 Sensor) for Gas Detector >>> Product description After the analog signal output by the oxygen electrochemical sensor is amplified by the module, it is sent into the ADC acquisition port of STM32 single-chip microcomputer. After the filtration operation inside the STM32 single-chip microcomputer, the oxygen concentration in the air is calculated and then output from the serial port. The module...
...Gas Sensor(O2 Sensor) for Gas Detector >>> Product description After the analog signal output by the oxygen electrochemical sensor is amplified by the module, it is sent into the ADC acquisition port of STM32 single-chip microcomputer. After the filtration operation inside the STM32 single-chip microcomputer, the oxygen concentration in the air is calculated and then output from the serial port. The module... more
Brand Name:ALPHASENSE
Place of Origin:Jiangsu, China
Warranty:1 year
40xv Oxygen Gas Sensor O2 Sensor for Gas Detector Based on ELECTROCHEMICAL Principle
-
... O2 Gas Analyzer for CEMS >>Overview The AG-UVll3 flue gas analyzer consists of components such as alight source, gas chamber, spectrometer, HMl module, interfaceboard,temperature sensor, electrochemical oxygen sensor, andexpandable modules. Based on ...
-
..., 3900P, 4700, 5250 respiratory gas monitors, 5250 RGM, AS/3, Biox 3740, Biox 3760, Cardiocap/5 with N-XOSAT option, CS/3, Modular Monitors with M-OSAT module, Modulus CD, Oxicap, Rascal II, S/5, TuffSat 3775 GE Healthcare > Corometrics 200SL, 400SL, 511,
..., 3900P, 4700, 5250 respiratory gas monitors, 5250 RGM, AS/3, Biox 3740, Biox 3760, Cardiocap/5 with N-XOSAT option, CS/3, Modular Monitors with M-OSAT module, Modulus CD, Oxicap, Rascal II, S/5, TuffSat 3775 GE Healthcare > Corometrics 200SL, 400SL, 511, more
Brand Name:Datex ohmeda
Model Number:OEM
Place of Origin:China
Compatible Datex Ohmeda Pulse Oximeter Probes , Db9 Pin Disposable Oxygen Sensor
-
...Sensor Reusable TS-F1-H ► Brief Introduction It can work for handheld pulse oximeters (GE Ohmeda TuffSat*, 3775), tabletop pulse oximeters (3700 series, 3800, 3900, 3900P), respiratory gas monitors (4700, 5250 RGM), CARESCAPE modular monitors and S/5, AS/3, CS/3 modular monitors with M-OSAT module, Cardiocap*/5 with N-XOSAT option. Prior to placing TruSignal SpO2 Reusable Sensor...
...Sensor Reusable TS-F1-H ► Brief Introduction It can work for handheld pulse oximeters (GE Ohmeda TuffSat*, 3775), tabletop pulse oximeters (3700 series, 3800, 3900, 3900P), respiratory gas monitors (4700, 5250 RGM), CARESCAPE modular monitors and S/5, AS/3, CS/3 modular monitors with M-OSAT module, Cardiocap*/5 with N-XOSAT option. Prior to placing TruSignal SpO2 Reusable Sensor... more
Brand Name:GE Datex-Ohmeda
Model Number:TS-F1-H
Minimum Order Quantity:1
GE DATEX-OHMEDA TruSignal SpO2 Adult Finger Sensor Reusable TS-F1-H 1m 3.3 ft
-
... electrochemical sensor operating system:ARM single -chip computer system processor:Low power consumption ARM Cortex-M7+Cortex-M4 dual-core processor Blood range range:0.000mg/L~2.000mg/L(BrAC) Gas range:0.000mg/100ml ~ 440mg/100ml (exhale blood and
-
... Datex-Ohmeda® equipment that require OxyTip+® sensors including Datex-Ohmeda® TuffSat®, 3775, 37xx Series, 3800, 3900, 3900P, 4700 and 5250 respiratory gas monitors, Cardiocap/5 with N-XOSAT option, S/5, AS/3, CS/3 Modular Monitors with M-OSAT module.
... Datex-Ohmeda® equipment that require OxyTip+® sensors including Datex-Ohmeda® TuffSat®, 3775, 37xx Series, 3800, 3900, 3900P, 4700 and 5250 respiratory gas monitors, Cardiocap/5 with N-XOSAT option, S/5, AS/3, CS/3 Modular Monitors with M-OSAT module. more
Brand Name:Ohmeda
Model Number:3067BD4A
Place of Origin:China
Datex - Ohmeda OxyTip OXY - OL3 spo2 adapter cable for patient monitor