...oxygen sensor suit for MOX-2 O2 Sensor Specification: Output signal in air: 9-14mV Circuit Interface: 3Pin Molex Connector Accuracy and repeatability: <1% volume of oxygen, after calibration in 100% oxygen Linearity error: <3% relative error Response time: <12 seconds, relative to 90% relative value Zero drift: <200uV placed in 100% nitrogen for 5 minutes Cross interference: <0.5% volume of oxygen...
...oxygen sensor suit for MOX-2 O2 Sensor Specification: Output signal in air: 9-14mV Circuit Interface: 3Pin Molex Connector Accuracy and repeatability: <1% volume of oxygen, after calibration in 100% oxygen Linearity error: <3% relative error Response time: <12 seconds, relative to 90% relative value Zero drift: <200uV placed in 100% nitrogen for 5 minutes Cross interference: <0.5% volume of oxygen... more
Brand Name:Envitec
Model Number:oom102-1
Place of Origin:germany
-
...oxygen sensor O2 sensor Measurement range: 0 % ... 100 % oxygen (at atmospheric pressure) Nominal sensor lifetime :≥ 1 000 000 % volume oxygen hours Output in ambient air: 13 mV ... 16 mV Electrical interface: 3 pin (Molex® 22-11-1031) Accuracy: meets ISO 80601-2-55 requirements Repeatability: < 1 % volume O2 at constant temperature and pressure Linearity error...
...oxygen sensor O2 sensor Measurement range: 0 % ... 100 % oxygen (at atmospheric pressure) Nominal sensor lifetime :≥ 1 000 000 % volume oxygen hours Output in ambient air: 13 mV ... 16 mV Electrical interface: 3 pin (Molex® 22-11-1031) Accuracy: meets ISO 80601-2-55 requirements Repeatability: < 1 % volume O2 at constant temperature and pressure Linearity error... more
Brand Name:Med Accessories
Model Number:OOM202
Place of Origin:China
Harmless OOM202 Oxygen Sensor , Multifunction Medical Oxygen Meter
-
... 100±20 μA in air Zero drift (-20 to 40°C) of 0.6% Response time < 15 s Repeatability < 2% signal value/monthly line Linearity of sex Specifications: Overload 30% O2 Resolution <15s Linear error < 1
-
... life-span for use in hospitals and other medical environments. It is an oxygen sensor with 3.5 mm headphone mono jack compatible with many instruments and incubators. The sensor cell offers superior performance with a stable linear output signal and only
-
...Sensor 270mV/V 3.5% Linearity Error Additional Information: Dynamic Performance Range Sensitivity Linearity Error PR9350/01 ±12 mm 110 mV/V 3.5% PR9350/02 ±25 mm 270 mV/V 3.5% PR9350/04 ±50 mm 270 mV/V 2.5% PR9350/06 ±75 mm 310 mV/V 2.0% PR9350/08 ±100 mm 310 mV/V 2.0% PR9350/12 ±150 mm 310 mV/V 1.5% Description: Surface contact sensor...
...Sensor 270mV/V 3.5% Linearity Error Additional Information: Dynamic Performance Range Sensitivity Linearity Error PR9350/01 ±12 mm 110 mV/V 3.5% PR9350/02 ±25 mm 270 mV/V 3.5% PR9350/04 ±50 mm 270 mV/V 2.5% PR9350/06 ±75 mm 310 mV/V 2.0% PR9350/08 ±100 mm 310 mV/V 2.0% PR9350/12 ±150 mm 310 mV/V 1.5% Description: Surface contact sensor... more
Brand Name:Emerson
Model Number:PR9350/02
Place of Origin:Germany
PR9350/02 EPRO Inductive Sensor 270mV/V 3.5% Linearity Error
-
IFM Pressure transmitter with ceramic measuring cell PA3029 Part Number: PA3029 Product Name: Pressure transmitter Oirgin: Germany Manufacturer: IFM Specification PA-0-1-RBR14-A-ZVG/US/ /V Precise linear 4...20 mA output signal High repeatability and low ...
IFM Pressure transmitter with ceramic measuring cell PA3029 Part Number: PA3029 Product Name: Pressure transmitter Oirgin: Germany Manufacturer: IFM Specification PA-0-1-RBR14-A-ZVG/US/ /V Precise linear 4...20 mA output signal High repeatability and low ... more
Brand Name:IFM
Model Number:PA3029
Place of Origin:Germany
Precise Linear IFM Inductive Sensor Pressure Transmitter PA3029
-
... LCD DRO Digital Readout Linear Scale Encoder Sensor For Milling Lathe Thanks to the dual frequency laser instrument and ingenious software created by Loksshun, the SDS5 DRO has up to 600 Non-linear Error Compensation Points on each axis. Contrastive...
-
...anesthesia (excluding xenon), intensive care, neonatal incubators, and general oxygen monitors. MOX2 sensors come with adapters that fit onto the sensor threads and are used to direct airflow to the sensor. MOX2 Oxygen Sensor Test Gas % O2 Error 50% He /
...anesthesia (excluding xenon), intensive care, neonatal incubators, and general oxygen monitors. MOX2 sensors come with adapters that fit onto the sensor threads and are used to direct airflow to the sensor. MOX2 Oxygen Sensor Test Gas % O2 Error 50% He / more
Brand Name:City
Model Number:MOX-1 MOX-2 MOX-3 MOX-4 Mox1 Mox2 Mox3 Mox4
Certification:CE
MOX-1 MOX-2 MOX-3 MOX-4 Medical Oxygen O2 Gas Sensor
-
...Oxygen Index Meter Introduction Limited Oxygen Index tester measures minimum oxygen concentration as necessary when specimen combustion. The oxygen sensor is Paramagnetic which has a precise, long life, less error rate and high reliability. It is totally compliant with the contents of standards like ASTM D2863, ISO 4589-2, NES 714 and so on. Standards: ASTM:ASTM D2863 ISO:ISO 4589-2 NES:NES 714 Features Paramagnetic Oxygen
...Oxygen Index Meter Introduction Limited Oxygen Index tester measures minimum oxygen concentration as necessary when specimen combustion. The oxygen sensor is Paramagnetic which has a precise, long life, less error rate and high reliability. It is totally compliant with the contents of standards like ASTM D2863, ISO 4589-2, NES 714 and so on. Standards: ASTM:ASTM D2863 ISO:ISO 4589-2 NES:NES 714 Features Paramagnetic Oxygen more
Brand Name:YUYANG
Model Number:COI
Place of Origin:CHINA
Paramagnetic Limited Oxygen Index Apparatus 9kg With 1 Year Warranty
-
...Oxygen Index Test Apparatus measures minimum oxygen concentration as necessary when specimen combustion. The oxygen sensor is adapted Paramagnetic Type which has a precise, long life, less error rate and high reliability. The Minimum Oxygen Index Test Apparatus meets the requirements of standards like ASTM D2863, ISO 4589-2, NES714 and so on. Features: 1. Oxygen sensor, accuracy<0.1%; 2. Touch screen setting of oxygen
...Oxygen Index Test Apparatus measures minimum oxygen concentration as necessary when specimen combustion. The oxygen sensor is adapted Paramagnetic Type which has a precise, long life, less error rate and high reliability. The Minimum Oxygen Index Test Apparatus meets the requirements of standards like ASTM D2863, ISO 4589-2, NES714 and so on. Features: 1. Oxygen sensor, accuracy<0.1%; 2. Touch screen setting of oxygen more
Brand Name:AI
Model Number:AOI
Place of Origin:CHINA
New Designed Minimum Oxygen Index Test Apparatus With Touch Screen by NES 714
-
...Oxygen Sensor 4-20mA RS485 0-10V Output Signal Oxygen sensor adopts high sensitivity gas detection probe, signal stability, high precision, has a wide measurement range, good linearity, easy to use, easy to install, suitable for heating boiler control, industrial process control, automobile exhaust diagnosis, monitoring environmental oxygen...
...Oxygen Sensor 4-20mA RS485 0-10V Output Signal Oxygen sensor adopts high sensitivity gas detection probe, signal stability, high precision, has a wide measurement range, good linearity, easy to use, easy to install, suitable for heating boiler control, industrial process control, automobile exhaust diagnosis, monitoring environmental oxygen... more
Brand Name:OEM
Place of Origin:China
Minimum Order Quantity:1
RS485 Gas Detection Sensor 4-20mA 0-10V Output Signal O2 Gas Sensor
-
... 8V/mm 4 V/mm 1.5 V/mm 0.8V/mm Linear error ≤±1% Frequency response 0~10KHz Power supply DC -24V Environment temperature Probe temperature -30℃~120℃/ extension cable -...
-
...sensor Product Details NVCT.4200C-15 rail voltage sensor model specifications and technical parameters Rated voltage (A) 4200V Product number NVCT.4200C-15 Measuring range 0~±6000V working principle Magnetic modulation Power supply voltage (V) ± 15 × (1 ± 5%) V Rated measurement output 25mA Basic error ≦±0.6 % Linearity error ≦0.1% Zero output error...
...sensor Product Details NVCT.4200C-15 rail voltage sensor model specifications and technical parameters Rated voltage (A) 4200V Product number NVCT.4200C-15 Measuring range 0~±6000V working principle Magnetic modulation Power supply voltage (V) ± 15 × (1 ± 5%) V Rated measurement output 25mA Basic error ≦±0.6 % Linearity error ≦0.1% Zero output error... more
Minimum Order Quantity:100
Payment Terms:T/T
Delivery Time:1-12 weeks
50us Response 4200VA Magnetic Modulation Voltage Sensor
-
IFM Pressure transmitter with ceramic measuring cell PA9020 Part Number: PA9020 Product Name: Pressure transmitter Oirgin: Germany Manufacturer: IFM Specificaiton: PA-400-SBR14-B-DVG/US/V Precise linear 0...10 V output signal High repeatability and low ...
IFM Pressure transmitter with ceramic measuring cell PA9020 Part Number: PA9020 Product Name: Pressure transmitter Oirgin: Germany Manufacturer: IFM Specificaiton: PA-400-SBR14-B-DVG/US/V Precise linear 0...10 V output signal High repeatability and low ... more
Brand Name:IFM
Model Number:PA9020
Place of Origin:Germany
PA9020 IFM Inductive Sensor , IFM Pressure Transmitter Switch
-
.... Incorrect installation will cause measurement errors. Pay special attention to one "surface" and two "line": 1) The sensor mounting surface and the surface to be measured must be fixed tightly, flat and stable, if installation surface is unevenness, it
-
... error +0.05%F.S Insulation resistance ≥2000MQ(100VDC) Sensitivity 1.6+0.2mV/V (30- 75kg),1.0+0.2mV/N (10kg) Output temperature influence +0.05%F.S/10C Non-linear error +0.05%F.S Zero point temperature effect +0.1 %F.S/10"C Hysteresis error +0.05%F
-
...Sensor - A Reliable Alternative to Alphasense 1.Overview KACISE’s EcoOxygen O2 Sensor is an eco-friendly, high-performance solution for oxygen detection, serving as a dependable alternative to Alphasense. Designed for applications such as air quality monitoring, medical oxygen systems, and industrial safety, it offers high precision, wide linearity...
...Sensor - A Reliable Alternative to Alphasense 1.Overview KACISE’s EcoOxygen O2 Sensor is an eco-friendly, high-performance solution for oxygen detection, serving as a dependable alternative to Alphasense. Designed for applications such as air quality monitoring, medical oxygen systems, and industrial safety, it offers high precision, wide linearity... more
Brand Name:KACISE
Model Number:KQT-O2
Place of Origin:CHINA
EcoOxygen O2 Sensor Electrochemical Two-Electrode Detection for Precise Oxygen Measurement
-
... the influence of gravity acceleration and air buoyancy on the conversion of different use sites, the performance indexes of the load cell mainly include linearity error, hysteresis error,
-
...Oxygen Index Tester -- Model COI Introduction: COI Oxygen Index tester measures minimum oxygen concentration as necessary when specimen combustion. Oxygen sensor of this equipment is Paramagnetic Type, which is precise, long lifetime, reliable and has less error rate. COI Oxygen...
...Oxygen Index Tester -- Model COI Introduction: COI Oxygen Index tester measures minimum oxygen concentration as necessary when specimen combustion. Oxygen sensor of this equipment is Paramagnetic Type, which is precise, long lifetime, reliable and has less error rate. COI Oxygen... more
Brand Name:LAB TECH
Model Number:COI
Place of Origin:China
COI Paramagnetic Method Limited Oxygen Index Tester
-
...Sensor Module for Arduino Description ACS712 5A Current Sensor is a current sensing board based on Allegro’s ACS712 magnetic linear current sensor IC. ACS712 can sense current up to bidirectional 5A with lower than 5% error. The sensor’s output is analog voltage(185mV/A). ACS712 5A Current Sensor...
...Sensor Module for Arduino Description ACS712 5A Current Sensor is a current sensing board based on Allegro’s ACS712 magnetic linear current sensor IC. ACS712 can sense current up to bidirectional 5A with lower than 5% error. The sensor’s output is analog voltage(185mV/A). ACS712 5A Current Sensor... more
Brand Name:OKYNEWSTAR
Model Number:OKY3311
Place of Origin:Guangdong China(Mainland)
5A ACS712 DC Detect Range Current Arduino Sensor Module ACS712ELC-05B