-
...15.5, PRNT4-24, PRNT4-40.5 series of high-voltage fuses for overload protection of oil-immersed transformers are suitable for use in power systems with AC rated frequency of 50Hz and rated voltage of 15.5kV, 24kV and 40.5 kV respectively. As the overload protection protection element for power transformer and other power equipment, the fuse is installed in the transformer oil of American type box transformer...
...15.5, PRNT4-24, PRNT4-40.5 series of high-voltage fuses for overload protection of oil-immersed transformers are suitable for use in power systems with AC rated frequency of 50Hz and rated voltage of 15.5kV, 24kV and 40.5 kV respectively. As the overload protection protection element for power transformer and other power equipment, the fuse is installed in the transformer oil of American type box transformer... more
Brand Name:xawh
Place of Origin:China
Certification:ISO9001-2000, TUV
-
... nsformers are suitable for use in power systems with AC rated frequency of 50Hz and rated voltage of 8.3kV, 9.9kV, 15.5kV,17.2kV, 23kV a nd 38kV respectively. As the overload protection protection element for power transformer and other power equipmen t,
-
1. Product description of (H)RW5 Type High Voltage Drop Out Fuse Our high voltage drop out fuse is wildly used in distribution power project and it is very popular in global markets. Outdoor Expulsion Drop-out Type Distribution Fuse Cutout 12KV-40.5kv ...
1. Product description of (H)RW5 Type High Voltage Drop Out Fuse Our high voltage drop out fuse is wildly used in distribution power project and it is very popular in global markets. Outdoor Expulsion Drop-out Type Distribution Fuse Cutout 12KV-40.5kv ... more
Brand Name:XG
Model Number:RW4...
Place of Origin:XIAN
D Type 35KV 40.5KV Drop Out Fuse For Transformer Protection
-
...Fuse Holder H3-9 250V 15A AGC Fuse Holder Bayonet Type 15 Amp 250 Volts Product Description For 6x30 6x32mm FUSES Contact Resistance: <0.02Ω Withstanding Voltage: >AC3000V lnsulation Resistance: DC500V 100mΩ Min Electrical Rating:15A@250V AC Body: PBT Bayonet type cap Terminals: nickle plated brass, soldering type. Mounted by nut. Nuts and washers are in separate packages. Item H3-9 Fuse...
...Fuse Holder H3-9 250V 15A AGC Fuse Holder Bayonet Type 15 Amp 250 Volts Product Description For 6x30 6x32mm FUSES Contact Resistance: <0.02Ω Withstanding Voltage: >AC3000V lnsulation Resistance: DC500V 100mΩ Min Electrical Rating:15A@250V AC Body: PBT Bayonet type cap Terminals: nickle plated brass, soldering type. Mounted by nut. Nuts and washers are in separate packages. Item H3-9 Fuse... more
Model Number:H3-9
Place of Origin:China
Certification:UL
Panel Mount Bayonet Fuse Holder H3-9 250V 15A AGC Fuse Holder 6x30 6x32mm
-
...Transformer - 12470Y 7200 Grounded Wye Primary, 208Y 120 Wye-n Secondary - Copper, KNAN Features: 1) 5-position tap changer 2) Bayonet fuses partial-range current-limiting fuses 3) Automatic action pressure relief device 4) Oil level gauge. 5) 4 position load break switch 6) Oil temperature gauge. 7) Pressure/vacuum gauge. 8) Drain valve with sampler. Specification: Product Name 225 KVA Pad Mount Transformer...
...Transformer - 12470Y 7200 Grounded Wye Primary, 208Y 120 Wye-n Secondary - Copper, KNAN Features: 1) 5-position tap changer 2) Bayonet fuses partial-range current-limiting fuses 3) Automatic action pressure relief device 4) Oil level gauge. 5) 4 position load break switch 6) Oil temperature gauge. 7) Pressure/vacuum gauge. 8) Drain valve with sampler. Specification: Product Name 225 KVA Pad Mount Transformer... more
Brand Name:WINLEY
Model Number:225 KVA
Place of Origin:CHINA
225 Kva Three Phase Isolation Transformer 100va-5000kva
-
... of 3.6-40.5KV to protect the voltage mutual-inductor from over loading and circuit break.(tested by-inductor from overloading and circ-uit break. (Tested by National ...
-
...℃ to +60℃ Relative humidity:≤75% yearly average Without dew, maximum 30 days at 95% Vibration Resistance 24 cycles at 15 min. each
-
...Fuse Clip Description This product is suitable for indoor AC 50HZ, rated voltage 3.6-40.5KV system as overload and short circuit protection of voltage transformer. (Passed the type test of the National High-voltage Electrical Appliance Quality Supervision and Testing Center, and the product complies with GB15166.2 and IEC282-1). Parameters Part No. XRNP1 Product Name Limiting Fuse
...Fuse Clip Description This product is suitable for indoor AC 50HZ, rated voltage 3.6-40.5KV system as overload and short circuit protection of voltage transformer. (Passed the type test of the National High-voltage Electrical Appliance Quality Supervision and Testing Center, and the product complies with GB15166.2 and IEC282-1). Parameters Part No. XRNP1 Product Name Limiting Fuse more
Brand Name:Tian Rui
Model Number:XRNP1
Place of Origin:China
High Breaking Capacity High Voltage HV Current Limiting Cut Out Fuse Clip
-
...15,OMS-25,OMS-36 Overhead pole mounted primary metering unit 1. Product introduction 1.1 Product type name and model: 15.5-36.5kV medium voltage overhead column mounted metering box and JLSZXW7-15/25/36 type combined transformer. 1.2 Product overview: This type of metering box is an outdoor dry three-phase primary metering unit. The medium voltage metering transformer is assembled by up to 3 single-phase current transformers...
...15,OMS-25,OMS-36 Overhead pole mounted primary metering unit 1. Product introduction 1.1 Product type name and model: 15.5-36.5kV medium voltage overhead column mounted metering box and JLSZXW7-15/25/36 type combined transformer. 1.2 Product overview: This type of metering box is an outdoor dry three-phase primary metering unit. The medium voltage metering transformer is assembled by up to 3 single-phase current transformers... more
Brand Name:Chuangyin
Model Number:OMS-15,OMS-25,OMS-36
Place of Origin:China
Medium Voltage 36.5kV Column Mounted Metering Box 2VT 2CT
-
... level and rated Output(VA)COSφ=0.8 Rated insulation level(kV) 0.5 1 0.5 1 LMZ1-0.5 15/5 10 (5) (2.5) 10 15 0.5/3 20/5 10 30/5 5 40/5 5 50/5 3 75/5 2 100/5 2 150/5 1 200/5 1 300/5 1 400/5 1 5 500/5 1 600/5 1 800/5 1 1000/5 1 10 15 20 50 1500/5 1 2000/5 1
-
...15-08B EI38 EI42 EI48 EI54 EI60 EI66 Power 230V AC encapsulated transformer Power Transformer: ※ EI 42 through hole transformer with thermal fuse ※ Operating temperature range: -10 ℃ to + 70 ℃ with full load ※ RoHS Compliance Product Electrical Specifications @ 25℃: Part Number Input Voltage Input Frequency Output Current Hi Pot Pri to Core Hi Pot Pri to Sec Hi Pot Sec to Core DB-15...
...15-08B EI38 EI42 EI48 EI54 EI60 EI66 Power 230V AC encapsulated transformer Power Transformer: ※ EI 42 through hole transformer with thermal fuse ※ Operating temperature range: -10 ℃ to + 70 ℃ with full load ※ RoHS Compliance Product Electrical Specifications @ 25℃: Part Number Input Voltage Input Frequency Output Current Hi Pot Pri to Core Hi Pot Pri to Sec Hi Pot Sec to Core DB-15... more
Brand Name:Shareway
Model Number:DB-15-08B
Place of Origin:Guangdong,shenzhen
230V AC Encapsulated Power Over Ethernet Transformer DB-15-08B EI38 EI42 EI48 EI54 EI60 EI66
-
...Transformer, Various Types are Available,Current up to 50A FEATURES: Power supply for VTRs Small surface mount current sensors Sensed current up to 15A; Frequency range up to 1MHz Very low primary DC resistance 1.5KV AC/3mA / 1S isolation (hipot) between windings TECHNICAL INFORMATION: High Current - primary rated for 15...
...Transformer, Various Types are Available,Current up to 50A FEATURES: Power supply for VTRs Small surface mount current sensors Sensed current up to 15A; Frequency range up to 1MHz Very low primary DC resistance 1.5KV AC/3mA / 1S isolation (hipot) between windings TECHNICAL INFORMATION: High Current - primary rated for 15... more
Brand Name:Shinhom
Model Number:ACSTE8.3 Series
Place of Origin:China
Ferrite Core Current Sense Transformer SMD Installation Various Types
-
... current 630A Brand name Original Packing & Delivery 1. Standard export wooden case 2. Customized Environmental Conditions 1. Ambient temperature: -15℃
-
...fuse switch Product Description 11KV Drop Cut Fuse Cut Outs are widely used for protection / isolation of distribution transformers, This specification not only stipulates the electrical and mechanical requirements of good quality drop out fuse cut outs but also specifies important constructional features to ensure uniformity and proper quality. Type 11KV DOFC/100 11KV DOFC/200 Rated Voltage(kV) 10-15 10-15
...fuse switch Product Description 11KV Drop Cut Fuse Cut Outs are widely used for protection / isolation of distribution transformers, This specification not only stipulates the electrical and mechanical requirements of good quality drop out fuse cut outs but also specifies important constructional features to ensure uniformity and proper quality. Type 11KV DOFC/100 11KV DOFC/200 Rated Voltage(kV) 10-15 10-15 more
Brand Name:XK
Model Number:11KV DOFC
Place of Origin:china
100A 200A 11kv Drop Out Fuse / High Voltage 11 Kv Do Fuse Long Service Life
-
... test: rated output: 5KV / 12mA 3, the output frequency: 60 / 50Hz Selectable) 4, the output waveform: sine wave distortion <2%, crest factor 1.3 ~ 1.5 5, the upper limit ...
-
...Transformer Substation Outdoor Integrated Substation Features: ZBW1-15 series package substation consists of three parts: transformer room, high voltage room and low voltage room. 1. High voltage sides is equipped with HXGN series RMU (aerogenesis type, compressed air type, vacuum type or SF6 type), equipped with LBS, fuse...
...Transformer Substation Outdoor Integrated Substation Features: ZBW1-15 series package substation consists of three parts: transformer room, high voltage room and low voltage room. 1. High voltage sides is equipped with HXGN series RMU (aerogenesis type, compressed air type, vacuum type or SF6 type), equipped with LBS, fuse... more
Brand Name:Tianan Electric
Model Number:ZBW1-15
Place of Origin:CHINA
15kV Package Compact Transformer Substation Outdoor Integrated Substation
-
...5KV QLFM Isolated phase enclosed bus duct is a kind of high-current transmission device which is extensively applied in generator main lead-out wire loop and power station Service/auxiliary Transformers. Standards IEC364-5-54/GB/T8349-2000/JB/T9639-1999 Ambient ℃ Relative humidity Daily averages ≤ 95%. Monthly average ≤ 90% IP IP40, IP54 Rated voltage kV 3.15...
...5KV QLFM Isolated phase enclosed bus duct is a kind of high-current transmission device which is extensively applied in generator main lead-out wire loop and power station Service/auxiliary Transformers. Standards IEC364-5-54/GB/T8349-2000/JB/T9639-1999 Ambient ℃ Relative humidity Daily averages ≤ 95%. Monthly average ≤ 90% IP IP40, IP54 Rated voltage kV 3.15... more
Brand Name:WETOWN
Model Number:QLFM
Place of Origin:CHINA
IP54 40.5KV 60Hz QLFM Isolated Phase Busduct
-
...transformer Substation for tender project Parameters No. Item Unit High Voltage Equipment Transformer Low Voltage Equipment 1 Rated Voltage Ue KV 7.2/12 6/0.4 10/0.4 0.4 2 Rated Capacity Se KVA 200~2500 50~800 Max:2*1250 3 Rated Current Le A 200~630 144/3600 100~3000 4 Rated Breaking Current A KA Load switch 400~630 Depends on Fuse 15-63 5 Rated Short Time Current(s) KA 20*(2) 12.5*(4) 15...
...transformer Substation for tender project Parameters No. Item Unit High Voltage Equipment Transformer Low Voltage Equipment 1 Rated Voltage Ue KV 7.2/12 6/0.4 10/0.4 0.4 2 Rated Capacity Se KVA 200~2500 50~800 Max:2*1250 3 Rated Current Le A 200~630 144/3600 100~3000 4 Rated Breaking Current A KA Load switch 400~630 Depends on Fuse 15-63 5 Rated Short Time Current(s) KA 20*(2) 12.5*(4) 15... more
Brand Name:HENGFENGYOU
Model Number:YB
Place of Origin:China
6kv to 35kv outdoor 3 Phase Mobile transformer Substation for tender project from China
-
...15 15kV Insulation Resistance Tester is suitable for measuring the resistance of various insulating materials, and insulation resistance of transformers, motors, cables and electrical equipment. Technical Data Function insulation resistance test, voltage test Base Conditions 23°C±5°C, below 75%RH Rated Voltage(V) 500V, 1kV, 2.5kV, 5kV...
...15 15kV Insulation Resistance Tester is suitable for measuring the resistance of various insulating materials, and insulation resistance of transformers, motors, cables and electrical equipment. Technical Data Function insulation resistance test, voltage test Base Conditions 23°C±5°C, below 75%RH Rated Voltage(V) 500V, 1kV, 2.5kV, 5kV... more
Brand Name:HAOMAI
Model Number:HIT-15
Place of Origin:China
High Voltage 15kV Insulation Resistance Testing Equipment Moistureproof 50T Ohm