Brand Name: LinkZone
Model Number: ZDMS0.6/5S-LZII
Certification: CCCF
Place of Origin: China
MOQ: 1set
Price: Negotiable
Payment Terms: T/T, L/C
Supply Ability: 2000sets per month
Delivery Time: 5~8 work days
Packaging Details: carton box,32*32*35cm
Product Name: Automatic Fire Water Monitor
Mode No.: ZDMS0.6/5S-LZII
Working Voltage: DC 36V
Rated Pressure: 0.6Mpa
Protection Radius: 20m
Rate of flow: 5L/s
Installation Height: 6~15m
Communication Mode: CAN bus
Monitoring Radius: 40m
Applicable voltage: AC 110V~240V
  • Product Details
  • Company Profile

Automatic Fire Water Monitor Automatic Fire Fighting System For Fire Protection Engineering


LinkZone Automatic Fire Water Monitor

Automatic Fire Fighting Monitors for Fire Protection Solutions

Features:

●365days uninterrupted video monitoring.

●360° horizontal rotate and 120° vertical rotate.

●High pressure,quick response ,long jet distance and large protection range.

IR thermal imaging detecting technology ensure accurate aiming.

●Applicable voltage range:AC 110V~240V.

Fire monitoring,Fire alarming and Fire extinguishing functions integrated.

●Water saving.

Remote control and automatically scanning.

What's an automatic fire water monitor?

Our Automatic Fire Water Monitor discharge large volumes of suppression agent from a single fixed location, and at high pressure to give it an excellent range of coverage.The Quick Response Fire Fighting Monitor has built-in infrared thermal imaging detector, UV flame detector, closed circuit television camera. Real time dynamic flame location.The Automatic Fire Water Monitor works with the external UV flame detector to eliminate the detection blind area and increase early warning range.


When the Automatic Fire Water Monitor receives the fire early warning signal (UV or IR signal),it's built-in IR flame detector will automatically rotate along with the water monitor and lock the flame for 3 seconds, then spray water to extinguish the fire. Otherwise, the water monitor will consider it as a false alarm, and the Automatic Fire Water Monitor will reset automatically.The time spent from fire started to fire targeted is less than 30 seconds.


Specifications:

ZDMS0.6/5S-LZIIZDMS0.6/10S-LZIIZDMS0.8/20S-LZIIZDMS0.9/30S-LZIIZDMS0.8/40S-LZIIZDMS0.8/50S-LZII

Working Voltage

DC36VDC36VDC24VDC24VDC24VDC24V
Rated Pressure0.6MPa0.6MPa0.8MPa0.9MPa0.8MPa0.8MPa
Protection Radius20m28m42m50m52m55m
Rate of flow5L/s10L/s20L/s30L/s40L/s50L/s
Installation Height6~15m6~15m8~35m8~35m8~35m8~35m
Jet radius34m39m56m62m67m73m
Positioning time≤30s≤30s≤60s≤60s≤60s≤60s
Monitoring radius40m40m60m60m80m80m
Flange ConnectionDN50DN50DN80DN80DN100DN100

Attention:

1.The side of cannon with label”this side to wall” must be faced to wall when installed.
2.Video line connected from DVR to cannon directly.
3.Signal lines must connect to signal lines of cannon where it is 2m from cannon.
4.Operation panel installed near the exit and 1.5m from ground,and from where operator can see all cannnons controlled by this operation panel.
5.Pls take care when handling cannon as there is UV detector at the bottom of cannon.The UV detetor is fragile.
6.Make sure there is no barrier around the cannon to stop the cannon 360 degree rotate.
7.The ground lead of DVR,earth wire and Lightning protection wire of control console need be connected to your ground lead.


Scope of applications:

Our Automatic Fire Water Monitor are wildly used in Industrial,commercial and residential fields.Such as airport, high-speed railway station, bus station, hotel atrium, museum, library, TV studio, gymnasium, science and technology museum, exhibition hall, convention center, theater, cinema, civic activity center, industrial plant, chemical plant, gas station, oil port,helicopter hangar, power plants, logistics centers, hospitals, large shopping malls, commercial complexes, colleges and universities, coal mines, warehouses and other places with large space.

FAQ:

Q1: Are you a manufacturer?

A1: Yes. We are a professional and No.1 manufacture of Automatic Fire Water Monitor which has the most advanced technology.
Q2: What certificates do you have?
A2: We only have CCCF and ISO certificate at present. And we plan to do FM certificate later.
Q3: What are the advantages of your Automatic Fire Monitor?
A3: Our Automatic Fire Monitor adopt the Infrared thermal imaging detecting and targeting technology. Our Fire Water Cannon integrates the following functions: 1. Remote Video Surveillance. 2. Fire Alarm. 3. Intelligent Fire Extinguishing.

Cheap Automatic Fire Water Monitor Automatic Fire Fighting System For Fire Protection Engineering for sale
Send your message to this supplier
 
*From:
*To: Henan LinkZone Fire Technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
Contact Us Quickly