Categories | Oxygen Gas Sensor |
---|---|
Brand Name: | CITY |
Model Number: | 2FO |
Place of Origin: | UK |
MOQ: | 1 |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 5000pcs/Month |
Delivery Time: | 3-5Workingdays |
Packaging Details: | Standard Box |
Nominal measurement range: | 0-25% |
Large load: | 30% |
Service life: | 2 years (in air) |
Output signal: | 0.41 ± 0.07ma (in air) |
t95 response time: | <10 seconds (see note) |
2FO Oxygen Sensor Two Year Life In Air Use For Fixed Gas Detector
It is suitable for measuring the oxygen content of flue gas by flue gas analyzer and measuring the combustion efficiency.
Specification:
Temperature range | -20°c to +45°c |
Temperature coefficient | 0.2% signal/°c |
Pressure range | atmospheric pressure ± 10% |
Humidity range | 0 to 99% rh intermittent work |
Long-term output drift | <5% signal loss/year |
The recommended load resistance | 100Ω |
Storage life | 6 months |
![]() |