| Categories | Biotechnology Lab Equipment |
|---|---|
| Brand Name: | NANBEI |
| Model Number: | Gentier48E |
| Certification: | CE |
| Place of Origin: | China |
| MOQ: | Negotiable |
| Payment Terms: | TT, LC, Paypal, Western Union, MoneyGram… |
| Delivery Time: | 7-10days |
| Price: | Negotiable |
| Sample capacity(wells): | 48 |
| Reaction volume: | 5-100ul |
| Consumables: | 0.2ml 8-strip tubes,0.2ml PCR single tube(Optical flat cap. Clear tube) |
| Gradient range: | 1℃-40℃ |
| Gradient block: | 8row |
| Special temperature protocol: | Gradient PCR, Long PCR, Touch Down PCR |
Real-time pcr system Gentier48
Advantage
1. 7 inch touch screen,easy to use software
2. Ultra UniF thermal platform
3. 2 seconds lateral optical scanning
4. Non-maintenance Optical System
5. Outstanding and powerful data analysis functions


Parameters
| Model | Gentier48E | Gentier48S | Gentier48R |
| Thermal block | |||
| Sample capacity(wells) | 48 | ||
| Reaction volume | 5-100ul | ||
| Consumables | 0.2ml 8-strip tubes,0.2ml PCR single tube(Optical flat cap. Clear tube) | ||
| Temperature range | 0℃-100℃ | ||
| Heating/cooling system | Peltier | ||
| Max heating rate | 8.0℃/sec | ||
| Average heating rate | 6.0℃/sec | ||
| Max cooling rate | 5.5℃/sec | ||
| Average cooling rate | 4.0℃/sec | ||
| Temperature accuracy | ±0.1℃ | ||
| Temperature uniformity | ±0.1℃ | ||
| Gradient range | 1℃-40℃ | N/A | 1℃-40℃ |
| Gradient block | 8row | 8row | |
| Special temperature protocol | Gradient PCR, Long PCR, Touch Down PCR | Long PCR, Touch Down PCR | Gradient PCR, Long PCR, Touch Down PCR |
| Heat Lid | |||
| Temperature range | Room temperature-110℃ | ||
| Optical system | |||
| Excitation Source | 4LEDs | 2LEDs | |
| Detector | Photodiode | ||
| Detection position | Excitation and scan from lateral | ||
| Detection method | 4 channels scanning at the same time, no edge effect | ||
| Detection time | 2 seconds for 48 wells for all channels | ||
| Range of excitation/emission wavelengths(nm) | 1. 465/510(FAM,SYBR Green I,SYTO9,Eva Green,LC Green) 2. 527/563(HEX,VIC,TET,JOE) 3. 580/616(ROX,Texas Red) 4. 632/664(Cy5) | 1.465/510(FAM,SYBR Green I,SYTO9,Eva Green, LC Green) 2. 527/563(HEX,VIC,TET,JOE) | |
| Probe Taqman Probe,Molecular beacons probe, scorpion probe | |||
| Multiplexing | Up to 4 targets | Up to 2 targets | |
| Fluorescence Linearity | r≥0.990 | ||
| Fluorescence Dynamic Range | Adjustable | ||
| Performance | |||
| Sample Linearity | /r/≥0.999 | ||
| Sample repeatability | Ct value CV≤0.5% | ||
| Sample dynamic Range | 1-1010 copies | ||
| Software Functions | |||
| Data Analysis Modes | Qualitative analysis, Absolute quantification, Relative quantification, Genotyping analysis, Endpoint analysis, Melt curve analysis, High Resolution Melting | ||
| Control Modes |
2. PC direct control 3.WLAN control(one PC can control max 10 unis, and device can be controlled by any PC in the WLAN) | ||
| Data Storage | Upload and download through USB disk, 1000 results can be stored in machine | ||
| Power failure protection | Automaticly start running experiments after power supply, no need wait PC software | ||
| Customize Report | Templetes reserved, report can customized | ||
| Administration Management | Administratior can set functions limits for users | ||
| Fault Management | Fault report and analysis,solution instruction | ||
| LIS connection | CSV,Excel,TXT format data output, open port for LIS connection | ||
| Others | |||
| PC operating system | Win7, Win 10 | ||
| Communication Port | 1 ethernet and 2 USB | ||
| Foot print(WxDxH) | 260mmX400mmX260mm | ||
| Weight | 11kg | ||
| Power usage | AC100 to 125V/200to 240V(50/60HZ) | ||
| Power consumption | 600VA | ||
| Work environment | Temperature:10℃~30℃ Humidity:20%~85% | ||
|