Home > Power Cables >

LSZH Class 2 Copper Conductor XLPE insulation and steel tape armored MV Cable IEC 60502 3 cores 300mm2

Categories Low Smoke Zero Halogen Power Cable
Brand Name: CHINT
Model Number: LSZH(WDZR-YJY22)
Certification: CE/SGS/KEMA
Place of Origin: CHINA
MOQ: Negotiable
Price: Negotiable
Supply Ability: 500km/month
Packaging Details: Wooden drum/iorn drum
Core: 1 or 3
Outer Sheath: LSZH
Insulation: XLPE
Rated Voltage: 6/10kv
Color: Orange Or black
Standard: IEC 60502,BS 6622,CB/T 12706,DIN VDE 0276
  • Product Details
  • Company Profile

LSZH Class 2 Copper Conductor XLPE insulation and steel tape armored MV Cable IEC 60502 3 cores 300mm2

LSZH Class 2 Copper Conductor XLPE insulation and steel tape armored MV Cable IEC 60502 3 cores 300mm2


Detailed Product Description


What is LSOH Power Cable
Typical structure of LSOH flame-retardant cable: non-metallic cable cladding material is LSOH flame-retardant material with different properties. This structure enables the cable to pass class A tests in IEC 60332-3-22 and related tests in IEC 60754 and IEC 61034
.
Benefits of FR Cable
When a fire occurs, the combustion of combustibles in the ordinary power system will produce a large amount of halogen-containing smoke. The LSOH power cable and the LSOH building materials used together can effectively reduce the total amount of smoke released by combustible combustion and the content of halogen, so as to reduce the casualty rate in the fire.
The cable has good radial compressive performance.

Constructions
Conductor : Compact stranded copper conductor, Cl.2 as per IEC 60228
Conductor Screen: Semi-conductor
Insulation : XLPE(cross-linked polyethylene) rated at 90 ℃
Insulation Screen: Semi-conductor
Screen : Copper tape
Interlining: LSOH Flame Retardant Polyolefin, black
Armouring: STA(Steel-Tape Armouring)
Sheath : LSOH Flame Retardant Polyolefin, black

Note:
Insulation identification as per standards or customer requirement

Applications
Laying in room ,tunnel ,cable trench ,and pipes.

Standards
International: IEC 60502, IEC 60228, IEC 60332, IEC 60754
China: GB∕T 12706.2-2008, GB∕T 19666-2005
Other standards such as BS,VDE and ICEA upon request

Technical data
Rated voltage: 6/10 kV
Maximum Conductor Temperature: under normal (90 ℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions.
Min. Ambient Temp.: The cable shall be pre heated if the ambient temperature is below 0℃
Min. Bending Radius: single core cable 20(d+D)±5%
Multi-core cable 15(d+D)±5%

Certificates
CE, SGS, KEMA and more others at request

Technical Specifications

Nom. Cross-section of conductorStrands No./Dia. Of ConductorInsulation
Thickness
Thickness of Copper StripThickness of steel tapeSheath ThicknessApprox. O.D.Approx.Max. D.C Resistance of Conductor (20 ℃)Testing Voltage A.CCurrent Rating
WeightIn air (A)In soil(A)
1×257/2.17+0.013.40.120.21.823.98720.72724165160
1×357/2.56+0.013.40.120.21.824.99990.52424205190
1×5019/1.86+0.013.40.120.21.826.211610.38724245225
1×7014/2.56+0.013.40.120.21.827.914130.26824305275
1×9519/2.56+0.023.40.120.21.929.717240.19324370330
1×12024/2.56+0.023.40.120.21.931.220000.15324430375
1×15030/2.56+0.013.40.120.22.032.823130.12424490425
1×18537/2.56+0.023.40.120.22.034.627290.099124560480
1×24048/2.58+0.023.40.120.52.138.837350.075424665555
1×30060/2.58+0.023.40.120.52.241.244040.060124765630
1×40060/2.93+0.023.40.120.52.344.554030.04724890725
1×50060/3.33+0.023.40.120.52.447.966170.0366241030825
1×63060/3.76+0.023.40.120.52.551.780850.0283241200950
3×257/2.17+0.013.40.100.52.446.131430.72724120125
3×357/2.56+0.013.40.100.52.448.335760.52424140155
3×5019/1.86+0.013.40.100.52.652.342290.38724165180
3×7014/2.56+0.013.40.100.52.756.351350.26824210220
3×9519/2.56+0.023.40.100.52.860.061570.19324255265
3×12024/2.56+0.023.40.100.52.963.671420.15324290300
3×15030/2.56+0.013.40.100.53.066.881670.12424330340
3×18537/2.56+0.023.40.100.53.171.196140.099124375380
3×24048/2.58+0.023.40.100.53.376.5117020.075424435435
3×30060/2.58+0.023.40.100.53.581.8138790.060124493485
3×40060/2.93+0.023.40.100.83.789.8178860.04724565520


Ordering Advice
Rated Voltage
Application Standard: IEC/BS/UL/GB
Number of Cores
Conductor Size & Construction
Type of Insulation
Armored or unarmored. If armor, the armor type & material
The Requirement of Sheath
Length of Cable & Packing Requirement
Other Requirement

Packing and shipping
steel wooden drum, other as required and shipping in general is by sea.


Cable Drum Data

CABLE DRUMSD1=Flange Diameter(mm)W=Useful Width (mm)D2=Barrel Diameter(mm)
1000700500
1100700550
1200700600
1400750710
1600900900
180011201000
240011501300



Product photo

Cheap LSZH Class 2 Copper Conductor XLPE insulation and steel tape armored MV Cable IEC 60502 3 cores 300mm2 for sale
Send your message to this supplier
 
*From:
*To: Zhejiang CHINT Cable Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0
Company Info
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
Contact Us Quickly