Categories | Motor Testing Machine |
---|---|
Brand Name: | AIP |
Model Number: | AIP89XX |
Place of Origin: | China |
MOQ: | 1 set |
Price: | Negotiable |
Payment Terms: | L/C, T/T |
Supply Ability: | 50 sets per month |
Delivery Time: | 45 working days |
Packaging Details: | Wooden case |
Product name: | Air conditioner motor testing machine |
Application: | Room air conditioner motor testing |
Station: | 2 stations |
Marks function: | Mark on the motor automatically |
Temperature compensation: | Yes |
Warranty: | 12 months |
Motor Testing Machine For Room Air Conditioner, Room Air Conditioner Motor Testing
1. Test object: air conditioner motor
2. Technical parameters
AC Hipot | |
test time range/resolution | 0.5~999.9s 0.1s/step |
Output voltage setting range and precision | AC 200~3000V ±(2%×setting value+10V) |
breakdown current testing range/precision | 0.10~20.00mA ±(2%×display value+0.05 mA) |
Hipot current presetting alarm range | Max:0.10~20.00mA;Min:0.00~20.00mA |
Direction of rotation | |
rotation | CW, CCW, still |
Insulation resistance | |
output voltage setting range/precision | DC 500V/1000V ±(2%×setting value+10V) |
insulation resistance testing range/precision | 1~500MΩ ≤100MΩ:±(3%×setting value+0.5MΩ) ;>100 MΩ:±(5%×setting value+5MΩ) |
insulation resistance alarm setting range | Max: 0~500MΩ; Min: 1~500MΩ |
test time range/resolution | 0.5~999s 0.1s/step |
DC winding resistance test | |
testing range and precision | 10.0mΩ~20KΩ ±(0.3%×display value+3 words) temperature compensation can be set. |
test time range/resolution | 0.5~999s 0.1s/step |
temperature compensation function | Yes |
temperature probe/range | DS18b20 -10.0℃~+50.0℃ |
precision | ±0.5°C(range: -10℃~+50℃) |
Surge | |
output voltage setting range/precision | 500~3000V ±(3%×display value+8V) |
sampling frequency | 100MHz |
waveform comparison | area, area difference, corona and phase 3 waveforms displayed in the testing interface |
No-load | |
voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 word) |
current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |
Low voltage start | |
voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 words) |
current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |
Stall | |
voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 word) |
current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |
3. After-sales service
Self-diagnose: the testing system has the function of self-diagnose, which could diagnose itself automatically and position the failure module when switch-on the testing system.Remote control: the service engineers will check the equipment status or failure via remote control in case of problem occurs.
Modular design makes the equipment can be maintained easily.
![]() |