Home > Remote Control >

TFT Touch Display Filling Controller Auto Zero Tracking With Load Cell

Categories Load Cell Display And Controller
Brand Name: Supmeter
Model Number: BST106-M10[FL]
Certification: CE
Place of Origin: China
MOQ: 1pcs
Price: Negotiation
Payment Terms: T/T, Western Union
Supply Ability: 10000pcs per month
Delivery Time: 3-10 working days
Packaging Details: 1pcs/box
Power Supply: DC24V
Max. Connect: 16Loadcells[350Ω]
Input: 9DIs
Output: 18DOs
COM@COM1: RS232
COM2: RS485
  • Product Details
  • Company Profile

TFT Touch Display Filling Controller Auto Zero Tracking With Load Cell

TFT Touch Display Filling Controller Auto Zero Tracking With Load Cell


Main Features:

  • EMC design with high anti-jam for industrial environment.
  • DC24V power input with reverse polarity protection.
  • Cortex-A8 CPU with 600MHz Clock, 128M Flash.
  • 7” [800×480] or 10.2” [1024×600] TFT touch panel.
  • 24-bit ∑-△ADC with internal resolution 1/1,000,000.
  • High sampling frequency 800Hz.
  • Special Anti-vibration Digital Filtering Algorithm for precise weighing, stable display and rapid response.
  • Auto Zero Tracking.
  • Fall Value Auto Correction.
  • Auto Pause for Deviation Alarm.
  • Auto Re-feed for Negative Deviation Alarm.
  • Target Batch Count & Target Batch Weight Control.
  • 3-speed[high/medium/low] feeding control by DOs or AOs.
  • Definable DI/DO/AO/COM[Communication Port].
  • Recipe Number: 100.

Technical Specification:

Power SupplyDC24V±20%,Max.10w.
DisplayHMI
Sampling Frequency600Hz
A/D Convert24-bit
LANOptional Ethernet
USB1Connect mouse, software download, data backup
Max. Connection number of Loadcell

16Loadcells (350Ω)

DI9 Normally Open Switch Inputs
DO18 Normally Open Transistor Switch Outputs
AO2Analog Signal Output: 4~20mA.
Operating Temperature-25℃~+45℃
Verification Accuracy0.02%
Filling Accuracy0.2%~0.5%

Main Operation Interface

Button Operation

NameOperationState IndicatorAuthorization
【Auto】Auto / Manual [Emergency Stop] switch.

Green: Auto state.

Grey: Manual state.

All Users
【Start】Start.

Green: Running state.

Grey: Stop state.

【Stop】Stop [Valid at Auto-running state].
【Re-run】Clear Alarm & Recover Running.
【E-stop】Emergency Stop.
【Alarm】

Alarm Query / Clear Alarm.

‘Auto/Pause’ state: Recover Running after clearing alarm.

Red: Alarm state.
【Print】Report Print.Green: Auto Print is allowed.
【Lock】

Screen-locking: Locking/unlocking the operating buttons of main display interface.

Auto Screen-locking: Refer to parameter [901].

Flashing Red: Locked.

Grey: Unlocked.

【Menu】Enter Main Menu.
【User】User Login. Display: Operator / Engineer / Admin.
【Lower】Manual Lower Filling Gun.Flashing Green: Filling Gun is moving down.
【Lift】Manual Lift Filling Gun.Flashing Red: Filling Gun is moving up.
【High】Manual Start/Stop High-speed filling.Green: Working state.
【Med】Manual Start/Stop Medium-speed Filling.
【Low】Manual Start/Stop Low-speed Filling.
【Zero】

Zero Fine Adjustment.

[No Power-down Protection]

Flashing Red.
【Tare】

Manual Tare.

[No Power-down Protection]

Flashing Red.
【Clear】Clear Screen: Clear the display values of Filling Weight, Totalized Weight and Batch Count.

Engineer

Administrator


Data Display & Quick Setting

NameDescriptionAuthorization
[NET]Net Weight [Weight Unit].
[FIL]Filling Process Ended.
[GROSS]Gross Weight.
[HIGH]Gross Weight Upper Limit Alarm.
[OVLD]Overload Alarm.
[PCS]Batch Count.
[FINAL]Final Filling Weight.
[▲]/[HI]Positive Deviation Alarm and ‘Deviation & Limit Set’.Administrator
[▼]/[LO]Negative Deviation Alarm and ‘Deviation & Limit Set’.
[TOT]Totalized Weight.
[Date&Time]Date&Time.
[RUN]Auto Running state.
[PAUSE]Pause state.
[DRUM]DI switch ‘Empty Drum Ready’ turned on.
[UP]Filling Gun Lift in Place.
[DOWN]Filling Gun Lowered in Place.
[HIT]Filling Gun Impacting Drum Alarm.
[ZERO]Gross Weight ≤ Non-load Zero Range.
[STAB]Weight is stable.
[FIN]Target Batch [Count/Weight] Finished.
[Highest Filling Position ]DI switch ‘Highest Step-filling Position Limit’ turned on.
[RECIPE]‘Working Recipe No.’ Selection.All Users
Recipe Parameter Setting.Engineer
[TARGET]‘Target Value’ Setting.All Users
[HIGH]‘SP1 Lead Value for High-speed Filling’ Setting.Engineer
‘DO Filling's Mode’ Parameter Setting.Administrator
[MED]‘SP2 Lead Value for Medium-speed Filling’ Setting.Engineer
‘DO Filling's Mode’ Parameter Setting.Administrator
[FALL]‘SP3 Fall Value for Low-speed Filling’ Setting.Engineer

‘Fall Value Auto Correction’ Parameter Setting.

  • ‘AUTO FALL’: Fall Value Auto Correction function is open.
  • ‘FREE FALL’: Fall Value Auto Correction function is closed.
Administrator
[MODE]APP1 Fill on Top / APP2 Fill on Bottom / APP3 Step-fill from Bottom. Refer to Parameter [300] ‘Application Mode’.
[BAT. CNT]‘Target Batch Count’ Setting.All Users
[BAT. WT]‘Target Batch Weight’ Setting.
[Label Print Information]Label title, No., Name and Checker Setting.


TFT-Touch Raiton Filling Controller For Filling Liquid, Gas & Powder Materials

Outline Size


Installation Mode

Terminal Diagram

System Diagram:


Cheap TFT Touch Display Filling Controller Auto Zero Tracking With Load Cell for sale
Send your message to this supplier
 
*From:
*To: CHANGSHA SUPMETER TECHNOLOGICAL CO.,LID
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
Contact Us Quickly