Home > Counters >

Insert doppler Ultrasonic Flow meter for volume flow measurement

Categories Ultrasonic Flow Meters
Brand Name: Purescience
Model Number: YE-TUF2000I
Certification: ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
Place of Origin: China
MOQ: 5 sets
Price: USD150-USD900
Supply Ability: 500 sets per month
Delivery Time: 3 weeks
Packaging Details: carton
Type: Insert
Name: Ultrasonic flow meter
display: LCD
Operation: Key boards
Output signal: 4-20 mA / OCT pulse / relay
Input: 3-way 4-20 mA (temperature, pressure and level)
Communication: RS485 / Modbus
Power supply: 8-36 VDC / 10-30 VAC
Pipe diameter: 15 mm - 6000mm
Pipe mount Material: weld steel, stainless steel, cast iron, copper / brass, cement pipe, aluminum
Accuracy: + / - 1%FS
  • Product Details
  • Company Profile

Insert doppler Ultrasonic Flow meter for volume flow measurement

The doppler Ultrasonic Flow meter for volume flow measurement


Function Description

Our inserter type doppler ultrasonic flowmeter for liquids applications, including but not limited to the metering of cooling water and demineralised water, control of batching and blending operations, mass flow measurement, allocation

measurement, district heating, irrigation, energy measurement, effluent, etc.

  • Independant of conductivity, viscosity, temperature, density and pressure
  • No moving or intruding parts, therefore no pressure loss or wear
  • Minimal operational and maintenance costs
  • Excellent long-term stability and reliability

Data sheet

Items

Performance & Parameter

Convertor

Principle

Transit-time ultrasonic flow meter

Accuracy

+ 1%

Operation

4 keyboards operation

Output signal

1 channel 4-20mA, resistance 0-1K , accuracy 0.1%

1 way OCT pulse (Pulse width: 6-1000ms, default: 200ms)

1 channel relay output

Input signal

3 way 4-20mA, accuracy: 0.1%, (temp., pressure, level)

Temperature transducer Pt100, heat / energy measurement

Communication

Galvanic isolation RS485, software upgrade by PC, MODBUS

Signal cable

Twisted-pair cable, 50m; RS485, transmission distance 1000m or above.

Connect port

Pipe material

Steel, stainless, cast iron, copper, cement, PVC, aluminum, etc

Pipe Dia

15 - 6000 mm

Straight pipe

Upstream: 10xDia, or downstream: 5xDia, and 30xDia from pump

Metering

Liquid type

Single sonic wave transmittable liquid, such as municipal water, cooling

water,

seawater water, waste water, pure water, Sewage with particle content, such

as oil, crude oil, lubrication oil, diesel oil, fuel oilChemicals, petrochemicals,

heating, ventilation ,air conditioner, power plants,


Temperature

-30-160℃


Turbidity

Up to 10000 ppm and less bubble


Flow velocity

0-7 m/s

Work environment

Temperature

Convertor: -20-60 ℃, Transducer: -30-160℃

Humidity

Convertor: 85%RH, Transducer: submersible up to depth 2m

Power supply

DC8-36V or AC10-30V / 1.5W

Dimension

Convertor: 95*95*35mm


Description:

The pipe type inline ultrasonic flowmeter is a precision instrument designed for linear, bi/directional volumetric flow

measurement of liquids. Flow measurement values can be output via the standard analog and-or pulse/frequency

outputs. Through a user friendly operator interface (HMI) the unit can be set up for a wide range of applications.

Next to actual volumetric flow measurement the unit can be configuredto perform flow totalization (plus, minus and

sum). Also measurement and output of the liquid sonic velocity can be configured. Optionally the unit can be set to

perform one of the following additional functions:

  • Calculate and output corrected standard volumetric or mass flow using external pressure & temperature inputs
  • Batch function
  • Heat function, combining T1, T2 and volume

Metering Diagram

Flow measurement Heat measurement

Reference chart

Type

Model

Pipe dia (mm)

Temperature

Dimension (mm)

Clamp on

TS-2

DN15-100

-30-90℃

45x25x32

TM-1

DN50-700

-30-90℃

64x39x44

TL-1

DN300-6000

-30-90℃

97x54x53

Clamp on (high temperature)

TS-2-HT

DN15-100

-30-90℃

45x25x32

TM-1-HT

DN50-700

-30-90℃

64x39x44

TL-1-HT

DN300-6000

-30-90℃

97x54x53

Insertion type

TC-1

DN80-6000

-30-90℃

190x80x55

TC-2(lengthen)

DN80-6000

-30-90℃

335x80x55

Pipe type

G3 (π type)

DN15-25

-30-160℃


G2

DN32/DN40

-30-160℃


G3

DN50-6000

-30-160℃



Optional temperature transducer

Specification

Model

Dia

Temp.

Water cut

Accuracy

Clamp-on temp. transducer Pt100

CT-1

>DN50

-40-160℃

No

100+ 0.8℃

Insertion temp. Transducer Pt100

TCT-1

Yes

Insertion temp. Pt100 with pressure

PCT-1

No

Insertion temp.Pt100 for small pipe D

SCT-1

<DN50

Yes


Industries

  • Chemicals
  • Petrochemicals
  • Oil & Gas
  • Heating, Ventilation & Air Conditioning (HVAC)
  • Power Plants
  • Water treatment

Applications

  • Metering of cooling water
  • Demineralisedwater
  • Control of batching and blending operations
  • Mass flow measurement
  • Allocation measurement
  • District heating
  • Irrigation
  • Energy measurement

Model Selection

I

Model









YF

Electromagnetic flowmeter


TF

Turbine


VF

Votex


LX

Vane wheel


T

Ultrasonic



E/F display mode

E: compact/local display, F: remote display




Pipe Dia

Type (mm)




xxxx

10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300,

400, 500, 600, 800, 1000




Code

Accuracy




1

+ 0.5% FS




2

+ 1.0% FS




3

+ 0.2% FS





Code

Type





N

Converter: 12 / 24 VDC, pulse output





A

Transmitter: 24VDC, 4-20mA outpt





B

Intelligent, Lion battery, no local display





G

Smart, local display, 4-20mA output





C1

Smart, local display, RS485





C2

Smart, local display, HART






Code

Type






S

Carbon steel housing






L

Stainless steel housing






G

High pressure housing






HL

316L electrode






HTi

Titanium electrode






HTa

Tantlum electrode






HC

Hastelloy-C electrode






L1

Liquid media






L2

Gas media






P

Pressure compensation






T

Temperature compensation






PT

Pressure&Temp. Compensation






F

PTFE liner






X

Rubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F,

Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt,

RS485, 316L electrode, liquid media meter, PTFE liner


Competitive Advantage:

  • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
  • CE approval
  • Strict process control
  • Advanced calibration equipment
  • Engineer team

Calibration

Work shop

Cheap Insert doppler Ultrasonic Flow meter for volume flow measurement for sale
Send your message to this supplier
 
*From:
*To: Shanghai Xunhui Environment Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
Contact Us Quickly