Categories | PSA Nitrogen Generator |
---|---|
Brand Name: | cape golden |
Model Number: | Cruise I |
Certification: | CE ISO |
Place of Origin: | BeiJing |
MOQ: | 1 |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Delivery Time: | 40 day |
flow: | 12L/min ﹫60-80psi |
Purity: | 97%~99.5% |
Dew dew point: | -50℃ |
Noise: | 52 db |
Electrical requirements: | 230V50/60Hz |
Power consumption: | 0.75 kw |
Shape dimensions: | 60*80*100 |
Weight: | 135kg |
Maximum altitude: | 2000 m |
Laboratory nitrogen generator Cruise Series(Cruise I)
Production Description:
Cruise Series:
In order to meet the demand of multi-channel nitrogen and air, we launched the cruiser series. The cruiser series is divided into three sub-series, respectively, cruise I, mainly aimed at AB liquid products more than 8050 series of liquid products, there is 1 channel nitrogen 1 channel air; cruiser III, mainly a number of liquid products, and their own compressed air station customers, good scalability, nitrogen flow range, can provide from 60 L/min -240L/min..
Cruise I
Features:
Good reliability: multi-channel design, non-interference, independent and stable;
Operational good :1 channel nitrogen ,2 channels air flow control alone, pressure control alone, easy to operate;
Good traceability: running time cumulative record, can trace the overall running time.
Cruise I technical parameters | |||
CruiseA212 | CruiseA224 | CruiseA218 | |
Curtain Gas (nitrogen) | 12L/min ﹫60-80psi | 24L/min ﹫60-80psi | 18L/min ﹫60-80psi |
Source Gas (air) | 24L/min ﹫110psi | 48L/min ﹫110psi | 26L/min ﹫110psi |
Exhaust Gas (air) | 8L/min ﹫60psi | 16L/min ﹫60psi | 25L/min ﹫60psi |
Nitrogen purity | 97%~99.5% | 97%~99.5% | 97%~99.5% |
Dew dew point | -50℃ | -50℃ | -50℃ |
Noise | 52 db | 52 db | 52 db |
Electrical requirements | 230V50/60Hz | 230V50/60Hz | 230V50/60Hz |
Power consumption | 0.75 kw | 1.45 kw | 1.45 kw |
phthalate | None | None | None |
Cleanliness | <0.01 u | <0.01 u | <0.01 u |
Residual liquid | None | None | None |
Maximum altitude | 2000 m | 2000 m | 2000 m |
Working environment | 5-35℃/41-95℉ | 5-35℃/41-95℉ | 5-35℃/41-95℉ |
Boot time | 30 min | 30 min | 30 min |
Nitrogen interface dimensions | ¢6 | ¢6 | ¢6 |
Shape dimensions | 60*80*100 | 60*120*140 | 60*120*140 |
Weight | kg 135 | 185 kg | 185 kg |
Features:
Good authenticity: the first domestic use of nitrogen purity on-line detector, real-time monitoring of nitrogen purity.
Good reliability: adopt multi-channel design, not dry each other, independent and steady;
Operational good :1 channel nitrogen ,2 channels air flow control alone, pressure control alone, easy to operate;
Good traceability: running time cumulative record, can be traced to the overall running time.
Applicable liquid type
AB: QTOF series 6600,5600+,4600, X-500R;
QTRAP Series SQ6500,SQ5500,SQ4500,4000,3200;