Home >

1 - 2 - 6 Leads Real time Personal ECG Monitor Automatically Diagnosis and Displays Arrhythmia

Categories Personal ECG Monitor
Place of Origin: China
Brand Name: Delfu
Certification: CFDA, CE
Model Number: Type DF-C03
MOQ: 100
Price: US$200~400 depends on quantity
Packaging Details: Regular package or Custom made
Delivery Time: 60~90 days
Payment Terms: FOB Shanghai
Supply Ability: 500PCS per week
  • Product Details
  • Company Profile

1 - 2 - 6 Leads Real time Personal ECG Monitor Automatically Diagnosis and Displays Arrhythmia

1 - 2 - 6 Leads Real time Personal ECG Monitor Automatically Diagnosis and Displays Arrhythmia


Quick Detail:


  • Delfu Personal ECG monitor real-time detects and displays ECG parameters, stores a large number of records and allows you playback records of your choice.
  • Puts both average person and patients in control of their heart health on occasional abnormal heartbeat feeling or in some emergency situations.
  • Automatically diagnosis and displays of arrhythmia during recording.
  • Provides accurate day-to-day ECG monitoring of 24 hours whether at home or clinic or office.
  • Wirelessly sends monitoring information by blue-teeth, output reports auto-saved in HTML documents, easy to upload and transfer to cell phone or computer for view and printout.
  • Portable, pocket size, lightweight, easy to carry, easy to use.
  • Be suitable for occasional abnormal heartbeat feeling, home/clinic monitoring of chronic heart patients, or patients with blood-pressure, diabetes, etc for diagnosis of cardiac symptoms.
  • Be available in some emergency situations for obtaining useful information immediately. While waiting for emergency and transportation help.


Description:

  1. Simple extremity lead measure during working relaxation,
    results one lead waveform.
  2. Extremity leads measure requires to be in still of sitting or lying down, when unwell feelings or routine monitoring, analyze 6 waveforms of I, II, III, aVL, aVR, aVF, determine whether heart rhythm is abnormal.
  3. Simulated extremity leads suitable for measure during physical exercise and slight movement dynamic monitoring (such as jogging, walking), analyze 6 waveforms of M Ⅰ, M Ⅱ, M Ⅲ, MaVL, MaVR, MaVF.
  4. Simulated precordial leads suitable for measure cardiac patients with a long time ambulatory monitoring, analyze waveform of MV1, MV5.
  5. Records and Displays Modes

(1) SD card used for record of a long time ambulatory monitoring and physical exercise monitoring.

(2) PAD or Mobile phone monitoring used for real time monitoring during business trip or travel.

Re: Android OS 2.3, 1024 x 600, double CPU, Blue teeth

(3) Desktop PC monitoring suitable for families, office occasions or community hospital usage.



Product Performances

  1. Real-time collection of monitoring ECG parameters, stores a large number of records and allows playback records of your choice.
  2. Real-time automatically diagnosis and displays arrhythmia during recording.
  3. Accurately analysis of ECG complexes, intervals, and segments of PR, provides high quality ECG tracing for cardiologist review.
  4. Automatic safety alarming while severe arrhythmia occurs in remote locations urgently, so as to obtain medical help and facilities as quickly as possible.
  5. Provides day to day ECG monitoring of 24-hours as Holter.
  6. The final collection automatically generates diagnostic output reports, can be saved as data file, which could be renamed and remarked.
  7. Output reports can be the HTML format.
  8. Analysis software can be installed for desktop computers and smart phones.
  9. Playback Mode used for pause, zoom, play back, to review output reports and scatter diagrams.

Applications:

DelfuReal time Portable ECG monitor widely used for below people and cases

  1. Patients with onset symptoms of (like) palpitations, dizziness, amaurosis, syncope, chest pain, chest tightness, if any abnormal heart rhythm occurs, provide monitoring results to doctors for diagnose reference.
  2. Being unwell, do self-ECG test immediately, and early stage of abnormal heart rhythm might be detected (and some heart disease is not necessarily manifested as cardiac discomfort).
  3. Being well, regular ECG test would be useful for early detection of asymptomatic abnormal heart rhythm.
  4. Patients of atria fibrillation, atrial flutter, ventricular tachycardia need long-term post-operative follow-up monitoring after radiofrequency ablation.
  5. Patients need long-term follow-up monitoring after cardiac interventional therapy and surgery.
  6. Patients need to be observed with the effects of taking anti-arrhythmic drugs.
  7. High blood pressure, diabetes to evaluate their drug’s efficacy by day-to-day monitoring.
  8. Community hospital uploads collected information to higher level hospital experts for diagnosing real-timely.
  9. For Routine physical examination, clinical research, long-term follow-up study of ECG variation, revealing the ECG regularity impacted by patients’ life, sports, medications efficacy.

Specifications:


FeaturesDECG Specification
Safety ClassClass II with internal power source BF type
Safety CriterionIEC60601-1(GB9706.1-2007)
 IEC60601-2-25(GB10793-2000)
Patient PopulationsAdults
Type of WaveformReal-time ECG waveforms displays
Heart Rate Range2~200 beats/Minute
Working modes and Leads1 lead for Simple extremity
6 leads for Extremity waveforms of I, II, III, aVL, aVR, aVF,
6 leads for Simulated extremity of MⅠ, MⅡ, M Ⅲ, MaVL, MaVR, MaVF.
2 leads for Simulated precordial of waveform of MV1, MV5.
Measurement Rate1000Hz/12 Channel AD (Double sync-channel)
Single Channel Input Resistance≥1MΩ(10Hz)
Dynamic Wave Range±3mVp-p
Frequency Range0.6Hz~40Hz
Output Recording ModesBlue teeth, Micro SD card

Output Receiving ModesPAD, Mobile(Android OS 2.3, 1024 x 600, double CPU)
Memory CardMicro SD card(Max 4G)
Battery Type3.7V/1200mA.h (Li-ion Rechargeable)
Power AdapterInput: 220VAC/50Hz 0.15A
Output: 5VDC 680mA
Storage ConditionsAmbient temperature:-20℃~+55℃
Relative humidity:25%~95%
Atmospheric pressure: 700hPa~1060hPa
Operating ConditionsAmbient temperature: +5℃~+35℃
Relative humidity:25%~80%(No condensate)
Atmospheric pressure: 860hPa~1060hPa
ComponentsPAD(Optional), ECG cable and lead wires, 4 Limp Clips Electrode, USB wire, Disposable ECG electrodes, Power Adapter, Li-ion Rechargeable Battery
Dimensions126mm×69mm×14.7mm
Weights78g

Competitive Advantage:


Background information on Arrhythmia

Arrhythmia is a common complication of acute myocardial infarction (Ml). It is one of the most important causes of death in patients with serious myocardial infarction. Approximately 72% to 90% of arrhythmias could result in serious myocardial infarction. However, if early ECG monitoring is applied almost 100% of arrhythmias could be diagnosed.


Its occurrence is characterized by:

1. The majority of arrhythmia appears within 48 hours after MI, approximately 90% of cases within the first 24 hours.

2. Ventricular arrhythmia is common , ventricular tachycardia takes up 10%~40%,and ventricular fibrillation 4% to 18 %.

3. Other serious arrhythmias such as branch block are often seen within 2 days of MI. MI patients should receive immediate ECG monitoring, whenever heart abnormalities are identified.

treatment measures should be urgently applied to prevent the occurrence of serious arrhythmias.


Not only the cardiac patients need ECG monitoring

The experts pointed out that accurate prediction of sudden cardiac death is an effective preventive measure. and early prevention interventions should be receive much more attention.

The survey shows that the city emerging industry groups under high tension are potential crowd of “sudden cardiac death”.


They may have no history of heart disease, no consciousness of cardiac abnormalities, but likely occasional mild symptoms, such as palpitation, chest tightness, tachycardia, and heartache, However, up to they go to hospital to take ECG treatment, normal ECG results might be, the causes not captured extactly at that time. The case defies diagnosis. Several similar incidents would lead to disease delays or ignored, that is so increase risk for life-threatening arrhythmias and sudden cardiac death.

Cheap 1 - 2 - 6  Leads Real time Personal ECG Monitor Automatically Diagnosis and Displays Arrhythmia for sale
Send your message to this supplier
 
*From:
*To: Jiangsu Delfu medical device Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
You may also be interested in :
Inquiry Cart 0
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    More from this Supplier
    Contact Us Quickly